Markus Wimmer to Aged, 80 and over
This is a "connection" page, showing publications Markus Wimmer has written about Aged, 80 and over.
Connection Strength
0.929
-
Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement. Clin Orthop Relat Res. 2017 Aug; 475(8):2027-2042.
Score: 0.072
-
Relationship of surface damage appearance and volumetric wear in retrieved TKR polyethylene liners. J Biomed Mater Res B Appl Biomater. 2017 10; 105(7):2053-2059.
Score: 0.069
-
How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study. Clin Orthop Relat Res. 2016 Aug; 474(8):1867-75.
Score: 0.067
-
Comparison of Antagonist Muscle Activity During Walking Between Total Knee Replacement and Control Subjects Using Unnormalized Electromyography. J Arthroplasty. 2016 06; 31(6):1331-1339.
Score: 0.067
-
Knee Flexion and Daily Activities in Patients following Total Knee Replacement: A Comparison with ISO Standard 14243. Biomed Res Int. 2015; 2015:157541.
Score: 0.065
-
Variability of TKR knee kinematics and relationship with gait kinetics: implications for total knee wear. Biomed Res Int. 2015; 2015:284513.
Score: 0.063
-
Methods for locating the tibio-femoral contact pathway in total knee replacements using marker-based gait analysis and standard radiography. Iowa Orthop J. 2014; 34:94-101.
Score: 0.058
-
Does hip implant positioning affect the peak external adduction moments of the healthy knees of subjects with total hip replacements? J Orthop Res. 2013 Aug; 31(8):1187-94.
Score: 0.055
-
Fine tuning total knee replacement contact force prediction algorithms using blinded model validation. J Biomech Eng. 2013 Feb; 135(2):021015.
Score: 0.055
-
Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res. 2012 Jul; 470(7):1814-25.
Score: 0.052
-
Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res. 2010 Apr; 28(4):436-43.
Score: 0.045
-
Surface topography of viable articular cartilage measured with scanning white light interferometry. Osteoarthritis Cartilage. 2009 Sep; 17(9):1197-203.
Score: 0.042
-
The novel protein PTPIP51 is expressed in human keratinocyte carcinomas and their surrounding stroma. J Cell Mol Med. 2008 Oct; 12(5B):2083-95.
Score: 0.040
-
Preoperative gait adaptations persist one year after surgery in clinically well-functioning total hip replacement patients. J Biomech. 2007; 40(15):3432-7.
Score: 0.037
-
Can a gait-dependent model predict wear on retrieved total knee arthroplasty components? Bone Joint J. 2020 Jun; 102-B(6_Supple_A):129-137.
Score: 0.023
-
Expanding instrumented gait testing in the community setting: A portable, depth-sensing camera captures joint motion in older adults. PLoS One. 2019; 14(5):e0215995.
Score: 0.021
-
3D detection of periodic limb movements in sleep. Annu Int Conf IEEE Eng Med Biol Soc. 2016 Aug; 2016:427-430.
Score: 0.017
-
Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem. J Bone Joint Surg Am. 2012 Oct 17; 94(20):1877-85.
Score: 0.013
-
Time course and extent of functional recovery during the first postoperative year after minimally invasive total hip arthroplasty with two different surgical approaches--a randomized controlled trial. J Biomech. 2011 Feb 03; 44(3):372-8.
Score: 0.012
-
Spinal kinematics and facet load transmission after total disc replacement. Spine (Phila Pa 1976). 2010 Oct 15; 35(22):E1160-6.
Score: 0.012
-
The biomechanical effects of focused muscle training on medial knee loads in OA of the knee: a pilot, proof of concept study. J Musculoskelet Neuronal Interact. 2010 Jun; 10(2):166-73.
Score: 0.011
-
Influence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints. Acta Orthop. 2009 Jun; 80(3):283-90.
Score: 0.011
-
Anti-apoptotic treatments prevent cartilage degradation after acute trauma to human ankle cartilage. Osteoarthritis Cartilage. 2009 Sep; 17(9):1244-51.
Score: 0.010
-
Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
Score: 0.010