Header Logo

Connection

Markus Wimmer to Prosthesis Design

This is a "connection" page, showing publications Markus Wimmer has written about Prosthesis Design.
Connection Strength

2.171
  1. Variability of TKR knee kinematics and relationship with gait kinetics: implications for total knee wear. Biomed Res Int. 2015; 2015:284513.
    View in: PubMed
    Score: 0.431
  2. An important contribution to our understanding of the performance of the current generation of metal-on-metal hip replacements. J Bone Joint Surg Am. 2013 Apr 17; 95(8):e53.
    View in: PubMed
    Score: 0.378
  3. Hip simulator wear testing according to the newly introduced standard ISO 14242. Proc Inst Mech Eng H. 2001; 215(5):429-42.
    View in: PubMed
    Score: 0.161
  4. Wear Characteristics of Conventional Ultrahigh-Molecular-Weight Polyethylene Versus Highly Cross-Linked Polyethylene in Total Ankle Arthroplasty. Foot Ankle Int. 2018 11; 39(11):1335-1344.
    View in: PubMed
    Score: 0.136
  5. Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement. Clin Orthop Relat Res. 2017 Aug; 475(8):2027-2042.
    View in: PubMed
    Score: 0.124
  6. How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study. Clin Orthop Relat Res. 2016 Aug; 474(8):1867-75.
    View in: PubMed
    Score: 0.115
  7. Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res. 2012 Jul; 470(7):1814-25.
    View in: PubMed
    Score: 0.089
  8. New insights into hard phases of CoCrMo metal-on-metal hip replacements. J Mech Behav Biomed Mater. 2012 Aug; 12:39-49.
    View in: PubMed
    Score: 0.088
  9. The tribological difference between biomedical steels and CoCrMo-alloys. J Mech Behav Biomed Mater. 2012 May; 9:50-62.
    View in: PubMed
    Score: 0.087
  10. New insights into wear and biological effects of metal-on-metal bearings. J Bone Joint Surg Am. 2011 May; 93 Suppl 2:76-83.
    View in: PubMed
    Score: 0.082
  11. In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
    View in: PubMed
    Score: 0.082
  12. Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res. 2010 Apr; 28(4):436-43.
    View in: PubMed
    Score: 0.076
  13. A case of disassociation of a modular femoral neck trunion after total hip arthroplasty. J Arthroplasty. 2006 Sep; 21(6):918-21.
    View in: PubMed
    Score: 0.060
  14. Investigation on stick phenomena in metal-on-metal hip joints after resting periods. Proc Inst Mech Eng H. 2006 Feb; 220(2):219-27.
    View in: PubMed
    Score: 0.057
  15. Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater. 2021 06; 118:104443.
    View in: PubMed
    Score: 0.041
  16. The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3. J Biomech. 2019 May 09; 88:104-112.
    View in: PubMed
    Score: 0.036
  17. Tractive forces during rolling motion of the knee: implications for wear in total knee replacement. J Biomech. 1997 Feb; 30(2):131-7.
    View in: PubMed
    Score: 0.031
  18. How have alternative bearings and modularity affected revision rates in total hip arthroplasty? Clin Orthop Relat Res. 2014 Dec; 472(12):3747-58.
    View in: PubMed
    Score: 0.026
  19. Graphitic tribological layers in metal-on-metal hip replacements. Science. 2011 Dec 23; 334(6063):1687-90.
    View in: PubMed
    Score: 0.022
  20. Influence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints. Acta Orthop. 2009 Jun; 80(3):283-90.
    View in: PubMed
    Score: 0.018
  21. Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
    View in: PubMed
    Score: 0.016
  22. Clinical performance of contemporary tibial polyethylene components. J Arthroplasty. 2006 Aug; 21(5):754-61.
    View in: PubMed
    Score: 0.015
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.