Header Logo

Connection

Markus Wimmer to Surface Properties

This is a "connection" page, showing publications Markus Wimmer has written about Surface Properties.
Connection Strength

1.507
  1. Design of a tribocorrosion bioreactor for the analysis of immune cell response to in situ generated wear products. J Long Term Eff Med Implants. 2014; 24(1):65-76.
    View in: PubMed
    Score: 0.118
  2. Tribolayer formation in a metal-on-metal (MoM) hip joint: an electrochemical investigation. J Mech Behav Biomed Mater. 2014 Jan; 29:199-212.
    View in: PubMed
    Score: 0.115
  3. Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res. 2012 Jul; 470(7):1814-25.
    View in: PubMed
    Score: 0.106
  4. What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium? J Mech Behav Biomed Mater. 2012 Apr; 8:71-85.
    View in: PubMed
    Score: 0.102
  5. New insights into wear and biological effects of metal-on-metal bearings. J Bone Joint Surg Am. 2011 May; 93 Suppl 2:76-83.
    View in: PubMed
    Score: 0.098
  6. In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
    View in: PubMed
    Score: 0.097
  7. Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res. 2010 Apr; 28(4):436-43.
    View in: PubMed
    Score: 0.091
  8. Surface topography of viable articular cartilage measured with scanning white light interferometry. Osteoarthritis Cartilage. 2009 Sep; 17(9):1197-203.
    View in: PubMed
    Score: 0.085
  9. A case of disassociation of a modular femoral neck trunion after total hip arthroplasty. J Arthroplasty. 2006 Sep; 21(6):918-21.
    View in: PubMed
    Score: 0.071
  10. Investigation on stick phenomena in metal-on-metal hip joints after resting periods. Proc Inst Mech Eng H. 2006 Feb; 220(2):219-27.
    View in: PubMed
    Score: 0.068
  11. [Size and shape of commercially available polyethylene particles for in-vitro and in-vivo-experiments]. Z Orthop Ihre Grenzgeb. 2004 May-Jun; 142(3):366-70.
    View in: PubMed
    Score: 0.060
  12. Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater. 2021 06; 118:104443.
    View in: PubMed
    Score: 0.048
  13. Hip simulator wear testing according to the newly introduced standard ISO 14242. Proc Inst Mech Eng H. 2001; 215(5):429-42.
    View in: PubMed
    Score: 0.048
  14. In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH. Med Eng Phys. 2018 02; 52:1-9.
    View in: PubMed
    Score: 0.039
  15. Tractive forces during rolling motion of the knee: implications for wear in total knee replacement. J Biomech. 1997 Feb; 30(2):131-7.
    View in: PubMed
    Score: 0.036
  16. Fretting-corrosion behavior in hip implant modular junctions: The influence of friction energy and pH variation. J Mech Behav Biomed Mater. 2016 09; 62:570-587.
    View in: PubMed
    Score: 0.035
  17. Intergranular pitting corrosion of CoCrMo biomedical implant alloy. J Biomed Mater Res B Appl Biomater. 2014 May; 102(4):850-9.
    View in: PubMed
    Score: 0.029
  18. Influence of corrosion on lipopolysaccharide affinity for two different titanium materials. J Prosthet Dent. 2013 Dec; 110(6):462-70.
    View in: PubMed
    Score: 0.029
  19. [Rotational bending test of hydroxylapatite plasma-coated models of TiAl6V4]. Biomed Tech (Berl). 1993 Jan-Feb; 38(1-2):14-6.
    View in: PubMed
    Score: 0.027
  20. Graphitic tribological layers in metal-on-metal hip replacements. Science. 2011 Dec 23; 334(6063):1687-90.
    View in: PubMed
    Score: 0.026
  21. Electrochemical behavior of titanium in artificial saliva: influence of pH. J Oral Implantol. 2014 Feb; 40(1):3-10.
    View in: PubMed
    Score: 0.025
  22. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study. Clin Oral Implants Res. 2012 Sep; 23(9):1055-62.
    View in: PubMed
    Score: 0.025
  23. The role of lipopolysaccharide on the electrochemical behavior of titanium. J Dent Res. 2011 May; 90(5):613-8.
    View in: PubMed
    Score: 0.024
  24. Influence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints. Acta Orthop. 2009 Jun; 80(3):283-90.
    View in: PubMed
    Score: 0.021
  25. Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
    View in: PubMed
    Score: 0.019
  26. Microvasculatory reaction of skeletal muscle to Ti-15Mo in comparison to well-established titanium alloys. J Mater Sci Mater Med. 2007 Oct; 18(10):2053-60.
    View in: PubMed
    Score: 0.019
  27. Clinical performance of contemporary tibial polyethylene components. J Arthroplasty. 2006 Aug; 21(5):754-61.
    View in: PubMed
    Score: 0.018
  28. Short-term microvascular response of striated muscle to cp-Ti, Ti-6Al-4V, and Ti-6Al-7Nb. J Orthop Res. 2006 Mar; 24(3):531-40.
    View in: PubMed
    Score: 0.017
  29. [Effect of surface hardness of the femur head prosthesis on abrasive wear forces in pairing with polyethylene for artificial hip joints]. Biomed Tech (Berl). 1998 Mar; 43(3):58-62.
    View in: PubMed
    Score: 0.010
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.