Markus Wimmer to Prosthesis Failure
This is a "connection" page, showing publications Markus Wimmer has written about Prosthesis Failure.
Connection Strength
4.375
-
Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement. Clin Orthop Relat Res. 2017 Aug; 475(8):2027-2042.
Score: 0.449
-
An important contribution to our understanding of the performance of the current generation of metal-on-metal hip replacements. J Bone Joint Surg Am. 2013 Apr 17; 95(8):e53.
Score: 0.343
-
Wear-corrosion synergism in a CoCrMo hip bearing alloy is influenced by proteins. Clin Orthop Relat Res. 2012 Nov; 470(11):3109-17.
Score: 0.333
-
Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res. 2012 Jul; 470(7):1814-25.
Score: 0.325
-
New insights into wear and biological effects of metal-on-metal bearings. J Bone Joint Surg Am. 2011 May; 93 Suppl 2:76-83.
Score: 0.300
-
In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
Score: 0.298
-
Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res. 2010 Apr; 28(4):436-43.
Score: 0.278
-
Relative importance of gait vs. joint positioning on hip contact forces after total hip replacement. J Orthop Res. 2009 Dec; 27(12):1576-82.
Score: 0.272
-
[Implant wear and aseptic loosening. An overview]. Orthopade. 2009 Aug; 38(8):690-7.
Score: 0.265
-
Wear particles. J Bone Joint Surg Am. 2006 Apr; 88 Suppl 2:99-102.
Score: 0.211
-
Investigation on stick phenomena in metal-on-metal hip joints after resting periods. Proc Inst Mech Eng H. 2006 Feb; 220(2):219-27.
Score: 0.208
-
Can a gait-dependent model predict wear on retrieved total knee arthroplasty components? Bone Joint J. 2020 Jun; 102-B(6_Supple_A):129-137.
Score: 0.141
-
Wear Characteristics of Conventional Ultrahigh-Molecular-Weight Polyethylene Versus Highly Cross-Linked Polyethylene in Total Ankle Arthroplasty. Foot Ankle Int. 2018 11; 39(11):1335-1344.
Score: 0.123
-
Fretting-corrosion behavior in hip implant modular junctions: The influence of friction energy and pH variation. J Mech Behav Biomed Mater. 2016 09; 62:570-587.
Score: 0.107
-
How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study. Clin Orthop Relat Res. 2016 Aug; 474(8):1867-75.
Score: 0.104
-
How have alternative bearings and modularity affected revision rates in total hip arthroplasty? Clin Orthop Relat Res. 2014 Dec; 472(12):3747-58.
Score: 0.096
-
Influence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints. Acta Orthop. 2009 Jun; 80(3):283-90.
Score: 0.066
-
Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
Score: 0.059
-
A case of disassociation of a modular femoral neck trunion after total hip arthroplasty. J Arthroplasty. 2006 Sep; 21(6):918-21.
Score: 0.054
-
[Systemic spread of wear debris--an in-vivo study]. Z Orthop Ihre Grenzgeb. 2006 Sep-Oct; 144(5):539-44.
Score: 0.054
-
Microvascular response of striated muscle to metal debris. A comparative in vivo study with titanium and stainless steel. J Bone Joint Surg Br. 2003 Jan; 85(1):133-41.
Score: 0.042
-
Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater. 2021 06; 118:104443.
Score: 0.037
-
Use of ultrasonic nebulizer with desolvator membrane for the determination of titanium and zirconium in human serum by means of inductively coupled plasma--mass spectroscopy. Fresenius J Anal Chem. 2000 Jan; 366(2):165-6.
Score: 0.034
-
A striated pattern of wear in ultrahigh-molecular-weight polyethylene components of Miller-Galante total knee arthroplasty. J Arthroplasty. 1998 Jan; 13(1):8-16.
Score: 0.030
-
In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH. Med Eng Phys. 2018 02; 52:1-9.
Score: 0.030
-
Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms. Acta Biomater. 2013 Sep; 9(9):8046-58.
Score: 0.022
-
Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem. J Bone Joint Surg Am. 2012 Oct 17; 94(20):1877-85.
Score: 0.021
-
Graphitic tribological layers in metal-on-metal hip replacements. Science. 2011 Dec 23; 334(6063):1687-90.
Score: 0.020
-
Polyethylene and metal wear particles: characteristics and biological effects. Semin Immunopathol. 2011 May; 33(3):257-71.
Score: 0.018
-
Clinical performance of contemporary tibial polyethylene components. J Arthroplasty. 2006 Aug; 21(5):754-61.
Score: 0.013
-
Novel route to fatigue-resistant fully sintered ultrahigh molecular weight polyethylene for knee prosthesis. Biomacromolecules. 2005 Mar-Apr; 6(2):942-7.
Score: 0.012
-
The influence of resting periods on friction in the artificial hip. Clin Orthop Relat Res. 2003 Feb; (407):127-38.
Score: 0.011