  1. Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement. Clin Orthop Relat Res. 2017 Aug; 475(8):2027-2042.
    View in: PubMed
    Score: 0.450
  2. Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res. 2012 Jul; 470(7):1814-25.
    View in: PubMed
    Score: 0.326
  3. In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
    View in: PubMed
    Score: 0.299
  4. Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res. 2010 Apr; 28(4):436-43.
    View in: PubMed
    Score: 0.279
  5. [Implant wear and aseptic loosening. An overview]. Orthopade. 2009 Aug; 38(8):690-7.
    View in: PubMed
    Score: 0.266
  6. Wear Characteristics of Conventional Ultrahigh-Molecular-Weight Polyethylene Versus Highly Cross-Linked Polyethylene in Total Ankle Arthroplasty. Foot Ankle Int. 2018 11; 39(11):1335-1344.
    View in: PubMed
    Score: 0.124
  7. Fretting-corrosion behavior in hip implant modular junctions: The influence of friction energy and pH variation. J Mech Behav Biomed Mater. 2016 09; 62:570-587.
    View in: PubMed
    Score: 0.107
  8. How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study. Clin Orthop Relat Res. 2016 Aug; 474(8):1867-75.
    View in: PubMed
    Score: 0.105
  9. How have alternative bearings and modularity affected revision rates in total hip arthroplasty? Clin Orthop Relat Res. 2014 Dec; 472(12):3747-58.
    View in: PubMed
    Score: 0.096
  10. Influence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints. Acta Orthop. 2009 Jun; 80(3):283-90.
    View in: PubMed
    Score: 0.066
  11. Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
    View in: PubMed
    Score: 0.059
  12. [Systemic spread of wear debris--an in-vivo study]. Z Orthop Ihre Grenzgeb. 2006 Sep-Oct; 144(5):539-44.
    View in: PubMed
    Score: 0.054
  13. Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater. 2021 06; 118:104443.
    View in: PubMed
    Score: 0.037
  14. Use of ultrasonic nebulizer with desolvator membrane for the determination of titanium and zirconium in human serum by means of inductively coupled plasma--mass spectroscopy. Fresenius J Anal Chem. 2000 Jan; 366(2):165-6.
    View in: PubMed
    Score: 0.034
  15. A striated pattern of wear in ultrahigh-molecular-weight polyethylene components of Miller-Galante total knee arthroplasty. J Arthroplasty. 1998 Jan; 13(1):8-16.
    View in: PubMed
    Score: 0.030
  16. In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH. Med Eng Phys. 2018 02; 52:1-9.
    View in: PubMed
    Score: 0.030
  17. Polyethylene and metal wear particles: characteristics and biological effects. Semin Immunopathol. 2011 May; 33(3):257-71.
    View in: PubMed
    Score: 0.018
  18. Clinical performance of contemporary tibial polyethylene components. J Arthroplasty. 2006 Aug; 21(5):754-61.
    View in: PubMed
    Score: 0.014
  19. The influence of resting periods on friction in the artificial hip. Clin Orthop Relat Res. 2003 Feb; (407):127-38.
    View in: PubMed
    Score: 0.011