Header Logo

Connection

Markus Wimmer to Biocompatible Materials

This is a "connection" page, showing publications Markus Wimmer has written about Biocompatible Materials.
Connection Strength

2.819
  1. Corrosion resistance of the nickel-free high-nitrogen steel FeCrMnMoN0.9 under simulated inflammatory conditions. J Biomed Mater Res B Appl Biomater. 2021 06; 109(6):902-910.
    View in: PubMed
    Score: 0.691
  2. Wear-corrosion synergism in a CoCrMo hip bearing alloy is influenced by proteins. Clin Orthop Relat Res. 2012 Nov; 470(11):3109-17.
    View in: PubMed
    Score: 0.397
  3. An autonomous mathematical reconstruction to effectively measure volume loss on retrieved polyethylene tibial inserts. J Biomed Mater Res B Appl Biomater. 2013 Apr; 101(3):449-57.
    View in: PubMed
    Score: 0.391
  4. The tribological difference between biomedical steels and CoCrMo-alloys. J Mech Behav Biomed Mater. 2012 May; 9:50-62.
    View in: PubMed
    Score: 0.376
  5. Investigation on stick phenomena in metal-on-metal hip joints after resting periods. Proc Inst Mech Eng H. 2006 Feb; 220(2):219-27.
    View in: PubMed
    Score: 0.248
  6. [Size and shape of commercially available polyethylene particles for in-vitro and in-vivo-experiments]. Z Orthop Ihre Grenzgeb. 2004 May-Jun; 142(3):366-70.
    View in: PubMed
    Score: 0.220
  7. Intergranular pitting corrosion of CoCrMo biomedical implant alloy. J Biomed Mater Res B Appl Biomater. 2014 May; 102(4):850-9.
    View in: PubMed
    Score: 0.107
  8. Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms. Acta Biomater. 2013 Sep; 9(9):8046-58.
    View in: PubMed
    Score: 0.103
  9. CoCrMo metal-on-metal hip replacements. Phys Chem Chem Phys. 2013 Jan 21; 15(3):746-56.
    View in: PubMed
    Score: 0.101
  10. Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res. 2010 Apr; 28(4):436-43.
    View in: PubMed
    Score: 0.083
  11. Short-term microvascular response of striated muscle to cp-Ti, Ti-6Al-4V, and Ti-6Al-7Nb. J Orthop Res. 2006 Mar; 24(3):531-40.
    View in: PubMed
    Score: 0.062
  12. Graphitic tribological layers in metal-on-metal hip replacements. Science. 2011 Dec 23; 334(6063):1687-90.
    View in: PubMed
    Score: 0.023
  13. Microvascular response of striated muscle to common arthroplasty-alloys: A comparative in vivo study with CoCrMo, Ti-6Al-4V, and Ti-6Al-7Nb. J Biomed Mater Res A. 2005 Oct 01; 75(1):31-40.
    View in: PubMed
    Score: 0.015
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.