This is a "connection" page, showing publications Markus Wimmer has written about Equipment Failure Analysis.
Connection Strength

2.690
  1. Relationship of surface damage appearance and volumetric wear in retrieved TKR polyethylene liners. J Biomed Mater Res B Appl Biomater. 2017 10; 105(7):2053-2059.
    View in: PubMed
    Score: 0.526
  2. Comparison of ISO standard and TKR patient axial force profiles during the stance phase of gait. Proc Inst Mech Eng H. 2012 Mar; 226(3):227-34.
    View in: PubMed
    Score: 0.389
  3. In-vivo kinematics of knee prostheses patients during level walking compared with the ISO force-controlled simulator standard. Proc Inst Mech Eng H. 2009 Oct; 223(7):889-96.
    View in: PubMed
    Score: 0.329
  4. Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: a comparison with the displacement-controlled ISO standard. J Biomech. 2009 Oct 16; 42(14):2363-8.
    View in: PubMed
    Score: 0.325
  5. [Size and shape of commercially available polyethylene particles for in-vitro and in-vivo-experiments]. Z Orthop Ihre Grenzgeb. 2004 May-Jun; 142(3):366-70.
    View in: PubMed
    Score: 0.226
  6. Wear-corrosion synergism in a CoCrMo hip bearing alloy is influenced by proteins. Clin Orthop Relat Res. 2012 Nov; 470(11):3109-17.
    View in: PubMed
    Score: 0.102
  7. Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res. 2012 Jul; 470(7):1814-25.
    View in: PubMed
    Score: 0.099
  8. New insights into wear and biological effects of metal-on-metal bearings. J Bone Joint Surg Am. 2011 May; 93 Suppl 2:76-83.
    View in: PubMed
    Score: 0.092
  9. In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
    View in: PubMed
    Score: 0.091
  10. Relative importance of gait vs. joint positioning on hip contact forces after total hip replacement. J Orthop Res. 2009 Dec; 27(12):1576-82.
    View in: PubMed
    Score: 0.083
  11. Do gait adaptations during stair climbing result in changes in implant forces in subjects with total hip replacements compared to normal subjects? Clin Biomech (Bristol, Avon). 2008 Jul; 23(6):754-61.
    View in: PubMed
    Score: 0.074
  12. Investigation on stick phenomena in metal-on-metal hip joints after resting periods. Proc Inst Mech Eng H. 2006 Feb; 220(2):219-27.
    View in: PubMed
    Score: 0.064
  13. [Comparison of total hip replacements cup orientation and position. Navigation vs. conventional manual implantation of hip prostheses]. Orthopade. 2005 Nov; 34(11):1131-6.
    View in: PubMed
    Score: 0.063
  14. Fluid composition impacts standardized testing protocols in ultrahigh molecular weight polyethylene knee wear testing. Proc Inst Mech Eng H. 2005 Nov; 219(6):457-64.
    View in: PubMed
    Score: 0.063
  15. Tribology approach to the engineering and study of articular cartilage. Tissue Eng. 2004 Sep-Oct; 10(9-10):1436-45.
    View in: PubMed
    Score: 0.058
  16. Use of ultrasonic nebulizer with desolvator membrane for the determination of titanium and zirconium in human serum by means of inductively coupled plasma--mass spectroscopy. Fresenius J Anal Chem. 2000 Jan; 366(2):165-6.
    View in: PubMed
    Score: 0.042
  17. Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
    View in: PubMed
    Score: 0.018
  18. Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation. J Biomed Mater Res B Appl Biomater. 2005 Jan 15; 72(1):206-14.
    View in: PubMed
    Score: 0.015
  19. The influence of resting periods on friction in the artificial hip. Clin Orthop Relat Res. 2003 Feb; (407):127-38.
    View in: PubMed
    Score: 0.013
  20. [Effect of surface hardness of the femur head prosthesis on abrasive wear forces in pairing with polyethylene for artificial hip joints]. Biomed Tech (Berl). 1998 Mar; 43(3):58-62.
    View in: PubMed
    Score: 0.009
  21. [Development and validation of a method for wear measurement of polyethylene hip acetabulum with metal backing using roentgen images]. Biomed Tech (Berl). 1998; 43 Suppl:66-7.
    View in: PubMed
    Score: 0.009