Markus Wimmer to Equipment Failure Analysis
This is a "connection" page, showing publications Markus Wimmer has written about Equipment Failure Analysis.
Connection Strength
2.690
-
Relationship of surface damage appearance and volumetric wear in retrieved TKR polyethylene liners. J Biomed Mater Res B Appl Biomater. 2017 10; 105(7):2053-2059.
Score: 0.526
-
Comparison of ISO standard and TKR patient axial force profiles during the stance phase of gait. Proc Inst Mech Eng H. 2012 Mar; 226(3):227-34.
Score: 0.389
-
In-vivo kinematics of knee prostheses patients during level walking compared with the ISO force-controlled simulator standard. Proc Inst Mech Eng H. 2009 Oct; 223(7):889-96.
Score: 0.329
-
Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: a comparison with the displacement-controlled ISO standard. J Biomech. 2009 Oct 16; 42(14):2363-8.
Score: 0.325
-
[Size and shape of commercially available polyethylene particles for in-vitro and in-vivo-experiments]. Z Orthop Ihre Grenzgeb. 2004 May-Jun; 142(3):366-70.
Score: 0.226
-
Wear-corrosion synergism in a CoCrMo hip bearing alloy is influenced by proteins. Clin Orthop Relat Res. 2012 Nov; 470(11):3109-17.
Score: 0.102
-
Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res. 2012 Jul; 470(7):1814-25.
Score: 0.099
-
New insights into wear and biological effects of metal-on-metal bearings. J Bone Joint Surg Am. 2011 May; 93 Suppl 2:76-83.
Score: 0.092
-
In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
Score: 0.091
-
Relative importance of gait vs. joint positioning on hip contact forces after total hip replacement. J Orthop Res. 2009 Dec; 27(12):1576-82.
Score: 0.083
-
Do gait adaptations during stair climbing result in changes in implant forces in subjects with total hip replacements compared to normal subjects? Clin Biomech (Bristol, Avon). 2008 Jul; 23(6):754-61.
Score: 0.074
-
Investigation on stick phenomena in metal-on-metal hip joints after resting periods. Proc Inst Mech Eng H. 2006 Feb; 220(2):219-27.
Score: 0.064
-
[Comparison of total hip replacements cup orientation and position. Navigation vs. conventional manual implantation of hip prostheses]. Orthopade. 2005 Nov; 34(11):1131-6.
Score: 0.063
-
Fluid composition impacts standardized testing protocols in ultrahigh molecular weight polyethylene knee wear testing. Proc Inst Mech Eng H. 2005 Nov; 219(6):457-64.
Score: 0.063
-
Tribology approach to the engineering and study of articular cartilage. Tissue Eng. 2004 Sep-Oct; 10(9-10):1436-45.
Score: 0.058
-
Use of ultrasonic nebulizer with desolvator membrane for the determination of titanium and zirconium in human serum by means of inductively coupled plasma--mass spectroscopy. Fresenius J Anal Chem. 2000 Jan; 366(2):165-6.
Score: 0.042
-
Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
Score: 0.018
-
Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation. J Biomed Mater Res B Appl Biomater. 2005 Jan 15; 72(1):206-14.
Score: 0.015
-
The influence of resting periods on friction in the artificial hip. Clin Orthop Relat Res. 2003 Feb; (407):127-38.
Score: 0.013
-
[Effect of surface hardness of the femur head prosthesis on abrasive wear forces in pairing with polyethylene for artificial hip joints]. Biomed Tech (Berl). 1998 Mar; 43(3):58-62.
Score: 0.009
-
[Development and validation of a method for wear measurement of polyethylene hip acetabulum with metal backing using roentgen images]. Biomed Tech (Berl). 1998; 43 Suppl:66-7.
Score: 0.009