Markus Wimmer to Polyethylene

This is a "connection" page, showing publications Markus Wimmer has written about Polyethylene.
Connection Strength

2.310
  1. Wear Characteristics of Conventional Ultrahigh-Molecular-Weight Polyethylene Versus Highly Cross-Linked Polyethylene in Total Ankle Arthroplasty. Foot Ankle Int. 2018 11; 39(11):1335-1344.
    View in: PubMed
    Score: 0.542
  2. How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study. Clin Orthop Relat Res. 2016 Aug; 474(8):1867-75.
    View in: PubMed
    Score: 0.458
  3. An autonomous mathematical reconstruction to effectively measure volume loss on retrieved polyethylene tibial inserts. J Biomed Mater Res B Appl Biomater. 2013 Apr; 101(3):449-57.
    View in: PubMed
    Score: 0.360
  4. Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res. 2012 Jul; 470(7):1814-25.
    View in: PubMed
    Score: 0.356
  5. Joint line elevation and tibial slope are associated with increased polyethylene wear in cruciate-retaining total knee replacement. J Orthop Res. 2020 07; 38(7):1596-1606.
    View in: PubMed
    Score: 0.154
  6. Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement. Clin Orthop Relat Res. 2017 Aug; 475(8):2027-2042.
    View in: PubMed
    Score: 0.123
  7. Polyethylene and metal wear particles: characteristics and biological effects. Semin Immunopathol. 2011 May; 33(3):257-71.
    View in: PubMed
    Score: 0.081
  8. Metal-on-metal bearing surfaces. J Am Acad Orthop Surg. 2009 Feb; 17(2):69-76.
    View in: PubMed
    Score: 0.070
  9. Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
    View in: PubMed
    Score: 0.065
  10. Sensitivity of total knee replacement wear to variability in motion and load input: A parametric finite element analysis study. J Orthop Res. 2020 07; 38(7):1538-1549.
    View in: PubMed
    Score: 0.039
  11. The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3. J Biomech. 2019 May 09; 88:104-112.
    View in: PubMed
    Score: 0.035
  12. How have alternative bearings and modularity affected revision rates in total hip arthroplasty? Clin Orthop Relat Res. 2014 Dec; 472(12):3747-58.
    View in: PubMed
    Score: 0.026