Markus Wimmer to Hip Prosthesis
This is a "connection" page, showing publications Markus Wimmer has written about Hip Prosthesis.
Connection Strength
5.434
-
Biotribometer for Assessment of Cell and Tissue Toxicity of Orthopedic Metal Implant Debris. Methods Mol Biol. 2022; 2394:713-725.
Score: 0.531
-
Articulation of an alumina-zirconia composite ceramic against living cartilage - An in vitro wear test. J Mech Behav Biomed Mater. 2020 03; 103:103531.
Score: 0.458
-
Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement. Clin Orthop Relat Res. 2017 Aug; 475(8):2027-2042.
Score: 0.380
-
An important contribution to our understanding of the performance of the current generation of metal-on-metal hip replacements. J Bone Joint Surg Am. 2013 Apr 17; 95(8):e53.
Score: 0.290
-
Does hip implant positioning affect the peak external adduction moments of the healthy knees of subjects with total hip replacements? J Orthop Res. 2013 Aug; 31(8):1187-94.
Score: 0.289
-
Wear-corrosion synergism in a CoCrMo hip bearing alloy is influenced by proteins. Clin Orthop Relat Res. 2012 Nov; 470(11):3109-17.
Score: 0.281
-
New insights into wear and biological effects of metal-on-metal bearings. J Bone Joint Surg Am. 2011 May; 93 Suppl 2:76-83.
Score: 0.253
-
In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
Score: 0.252
-
Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res. 2010 Apr; 28(4):436-43.
Score: 0.235
-
Relative importance of gait vs. joint positioning on hip contact forces after total hip replacement. J Orthop Res. 2009 Dec; 27(12):1576-82.
Score: 0.230
-
[Implant wear and aseptic loosening. An overview]. Orthopade. 2009 Aug; 38(8):690-7.
Score: 0.224
-
Metal-on-metal bearing surfaces. J Am Acad Orthop Surg. 2009 Feb; 17(2):69-76.
Score: 0.217
-
Orientation of the acetabular component. A comparison of five navigation systems with conventional surgical technique. J Bone Joint Surg Br. 2006 Oct; 88(10):1401-5.
Score: 0.184
-
A case of disassociation of a modular femoral neck trunion after total hip arthroplasty. J Arthroplasty. 2006 Sep; 21(6):918-21.
Score: 0.183
-
Investigation on stick phenomena in metal-on-metal hip joints after resting periods. Proc Inst Mech Eng H. 2006 Feb; 220(2):219-27.
Score: 0.176
-
Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater. 2021 06; 118:104443.
Score: 0.125
-
Hip simulator wear testing according to the newly introduced standard ISO 14242. Proc Inst Mech Eng H. 2001; 215(5):429-42.
Score: 0.124
-
In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH. Med Eng Phys. 2018 02; 52:1-9.
Score: 0.101
-
Fretting-corrosion behavior in hip implant modular junctions: The influence of friction energy and pH variation. J Mech Behav Biomed Mater. 2016 09; 62:570-587.
Score: 0.090
-
How have alternative bearings and modularity affected revision rates in total hip arthroplasty? Clin Orthop Relat Res. 2014 Dec; 472(12):3747-58.
Score: 0.081
-
Design of a tribocorrosion bioreactor for the analysis of immune cell response to in situ generated wear products. J Long Term Eff Med Implants. 2014; 24(1):65-76.
Score: 0.076
-
European multidisciplinary consensus statement on the use and monitoring of metal-on-metal bearings for total hip replacement and hip resurfacing. Orthop Traumatol Surg Res. 2013 May; 99(3):263-71.
Score: 0.072
-
[Rotational bending test of hydroxylapatite plasma-coated models of TiAl6V4]. Biomed Tech (Berl). 1993 Jan-Feb; 38(1-2):14-6.
Score: 0.071
-
Consensus statement "Current evidence on the management of metal-on-metal bearings"--April 16, 2012. Hip Int. 2013 Jan-Feb; 23(1):2-5.
Score: 0.071
-
Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem. J Bone Joint Surg Am. 2012 Oct 17; 94(20):1877-85.
Score: 0.070
-
The tribological difference between biomedical steels and CoCrMo-alloys. J Mech Behav Biomed Mater. 2012 May; 9:50-62.
Score: 0.067
-
Graphitic tribological layers in metal-on-metal hip replacements. Science. 2011 Dec 23; 334(6063):1687-90.
Score: 0.066
-
Influence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints. Acta Orthop. 2009 Jun; 80(3):283-90.
Score: 0.055
-
Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
Score: 0.050
-
The influence of resting periods on friction in the artificial hip. Clin Orthop Relat Res. 2003 Feb; (407):127-38.
Score: 0.036
-
Use of ultrasonic nebulizer with desolvator membrane for the determination of titanium and zirconium in human serum by means of inductively coupled plasma--mass spectroscopy. Fresenius J Anal Chem. 2000 Jan; 366(2):165-6.
Score: 0.029
-
[Effect of surface hardness of the femur head prosthesis on abrasive wear forces in pairing with polyethylene for artificial hip joints]. Biomed Tech (Berl). 1998 Mar; 43(3):58-62.
Score: 0.025
-
[Development and validation of a method for wear measurement of polyethylene hip acetabulum with metal backing using roentgen images]. Biomed Tech (Berl). 1998; 43 Suppl:66-7.
Score: 0.025
-
Time course and extent of functional recovery during the first postoperative year after minimally invasive total hip arthroplasty with two different surgical approaches--a randomized controlled trial. J Biomech. 2011 Feb 03; 44(3):372-8.
Score: 0.015