Header Logo

Connection

Markus Wimmer to Materials Testing

This is a "connection" page, showing publications Markus Wimmer has written about Materials Testing.
Connection Strength

2.716
  1. Backside wear of tibial polyethylene components is affected by gait pattern: A knee simulator study using rare earth tracer technology. J Orthop Res. 2020 07; 38(7):1607-1616.
    View in: PubMed
    Score: 0.666
  2. Wear measurement of highly cross-linked UHMWPE using a 7Be tracer implantation technique. J Biomed Mater Res B Appl Biomater. 2013 Apr; 101(3):423-9.
    View in: PubMed
    Score: 0.401
  3. [Size and shape of commercially available polyethylene particles for in-vitro and in-vivo-experiments]. Z Orthop Ihre Grenzgeb. 2004 May-Jun; 142(3):366-70.
    View in: PubMed
    Score: 0.219
  4. Hip simulator wear testing according to the newly introduced standard ISO 14242. Proc Inst Mech Eng H. 2001; 215(5):429-42.
    View in: PubMed
    Score: 0.174
  5. Wear Characteristics of Conventional Ultrahigh-Molecular-Weight Polyethylene Versus Highly Cross-Linked Polyethylene in Total Ankle Arthroplasty. Foot Ankle Int. 2018 11; 39(11):1335-1344.
    View in: PubMed
    Score: 0.146
  6. Finite element evaluation of the newest ISO testing standard for polyethylene total knee replacement liners. Proc Inst Mech Eng H. 2018 Jun; 232(6):545-552.
    View in: PubMed
    Score: 0.144
  7. Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement. Clin Orthop Relat Res. 2017 Aug; 475(8):2027-2042.
    View in: PubMed
    Score: 0.133
  8. Fretting-corrosion behavior in hip implant modular junctions: The influence of friction energy and pH variation. J Mech Behav Biomed Mater. 2016 09; 62:570-587.
    View in: PubMed
    Score: 0.126
  9. Design of a tribocorrosion bioreactor for the analysis of immune cell response to in situ generated wear products. J Long Term Eff Med Implants. 2014; 24(1):65-76.
    View in: PubMed
    Score: 0.107
  10. The tribological difference between biomedical steels and CoCrMo-alloys. J Mech Behav Biomed Mater. 2012 May; 9:50-62.
    View in: PubMed
    Score: 0.093
  11. What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium? J Mech Behav Biomed Mater. 2012 Apr; 8:71-85.
    View in: PubMed
    Score: 0.092
  12. In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
    View in: PubMed
    Score: 0.088
  13. Investigation on stick phenomena in metal-on-metal hip joints after resting periods. Proc Inst Mech Eng H. 2006 Feb; 220(2):219-27.
    View in: PubMed
    Score: 0.062
  14. Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater. 2021 06; 118:104443.
    View in: PubMed
    Score: 0.044
  15. In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH. Med Eng Phys. 2018 02; 52:1-9.
    View in: PubMed
    Score: 0.035
  16. Intergranular pitting corrosion of CoCrMo biomedical implant alloy. J Biomed Mater Res B Appl Biomater. 2014 May; 102(4):850-9.
    View in: PubMed
    Score: 0.027
  17. Influence of corrosion on lipopolysaccharide affinity for two different titanium materials. J Prosthet Dent. 2013 Dec; 110(6):462-70.
    View in: PubMed
    Score: 0.026
  18. New insights into hard phases of CoCrMo metal-on-metal hip replacements. J Mech Behav Biomed Mater. 2012 Aug; 12:39-49.
    View in: PubMed
    Score: 0.024
  19. Electrochemical behavior of titanium in artificial saliva: influence of pH. J Oral Implantol. 2014 Feb; 40(1):3-10.
    View in: PubMed
    Score: 0.023
  20. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study. Clin Oral Implants Res. 2012 Sep; 23(9):1055-62.
    View in: PubMed
    Score: 0.023
  21. The role of lipopolysaccharide on the electrochemical behavior of titanium. J Dent Res. 2011 May; 90(5):613-8.
    View in: PubMed
    Score: 0.022
  22. Fluid composition impacts standardized testing protocols in ultrahigh molecular weight polyethylene knee wear testing. Proc Inst Mech Eng H. 2005 Nov; 219(6):457-64.
    View in: PubMed
    Score: 0.015
  23. Novel route to fatigue-resistant fully sintered ultrahigh molecular weight polyethylene for knee prosthesis. Biomacromolecules. 2005 Mar-Apr; 6(2):942-7.
    View in: PubMed
    Score: 0.014
  24. Impact of a nickel-reduced stainless steel implant on striated muscle microcirculation: a comparative in vivo study. J Biomed Mater Res. 2001 Dec 05; 57(3):404-12.
    View in: PubMed
    Score: 0.012
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.