Markus Wimmer to Alloys
This is a "connection" page, showing publications Markus Wimmer has written about Alloys.
Connection Strength
1.917
-
Nickel-free high-nitrogen austenitic steel outperforms CoCrMo alloy regarding tribocorrosion in simulated inflammatory synovial fluids. J Orthop Res. 2022 06; 40(6):1397-1408.
Score: 0.742
-
Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: synergistic interactions of wear and corrosion. J Biomed Mater Res B Appl Biomater. 2012 Aug; 100(6):1662-71.
Score: 0.391
-
Tribolayer formation in a metal-on-metal (MoM) hip joint: an electrochemical investigation. J Mech Behav Biomed Mater. 2014 Jan; 29:199-212.
Score: 0.106
-
Effect of tribolayer formation on corrosion of CoCrMo alloys investigated using scanning electrochemical microscopy. Anal Chem. 2013 Aug 06; 85(15):7159-66.
Score: 0.105
-
CoCrMo metal-on-metal hip replacements. Phys Chem Chem Phys. 2013 Jan 21; 15(3):746-56.
Score: 0.102
-
The tribological difference between biomedical steels and CoCrMo-alloys. J Mech Behav Biomed Mater. 2012 May; 9:50-62.
Score: 0.095
-
Microvasculatory reaction of skeletal muscle to Ti-15Mo in comparison to well-established titanium alloys. J Mater Sci Mater Med. 2007 Oct; 18(10):2053-60.
Score: 0.069
-
Short-term microvascular response of striated muscle to cp-Ti, Ti-6Al-4V, and Ti-6Al-7Nb. J Orthop Res. 2006 Mar; 24(3):531-40.
Score: 0.063
-
Microvascular response of striated muscle to common arthroplasty-alloys: A comparative in vivo study with CoCrMo, Ti-6Al-4V, and Ti-6Al-7Nb. J Biomed Mater Res A. 2005 Oct 01; 75(1):31-40.
Score: 0.061
-
In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH. Med Eng Phys. 2018 02; 52:1-9.
Score: 0.036
-
Fretting-corrosion behavior in hip implant modular junctions: The influence of friction energy and pH variation. J Mech Behav Biomed Mater. 2016 09; 62:570-587.
Score: 0.032
-
Influence of corrosion on lipopolysaccharide affinity for two different titanium materials. J Prosthet Dent. 2013 Dec; 110(6):462-70.
Score: 0.027
-
[Rotational bending test of hydroxylapatite plasma-coated models of TiAl6V4]. Biomed Tech (Berl). 1993 Jan-Feb; 38(1-2):14-6.
Score: 0.025
-
New insights into hard phases of CoCrMo metal-on-metal hip replacements. J Mech Behav Biomed Mater. 2012 Aug; 12:39-49.
Score: 0.024
-
Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study. Clin Oral Implants Res. 2012 Sep; 23(9):1055-62.
Score: 0.023
-
Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation. J Biomed Mater Res B Appl Biomater. 2005 Jan 15; 72(1):206-14.
Score: 0.015