Markus Wimmer to Corrosion
This is a "connection" page, showing publications Markus Wimmer has written about Corrosion.
Connection Strength
1.334
-
Biotribometer for Assessment of Cell and Tissue Toxicity of Orthopedic Metal Implant Debris. Methods Mol Biol. 2022; 2394:713-725.
Score: 0.190
-
Nickel-free high-nitrogen austenitic steel outperforms CoCrMo alloy regarding tribocorrosion in simulated inflammatory synovial fluids. J Orthop Res. 2022 06; 40(6):1397-1408.
Score: 0.185
-
Corrosion resistance of the nickel-free high-nitrogen steel FeCrMnMoN0.9 under simulated inflammatory conditions. J Biomed Mater Res B Appl Biomater. 2021 06; 109(6):902-910.
Score: 0.175
-
Design of a tribocorrosion bioreactor for the analysis of immune cell response to in situ generated wear products. J Long Term Eff Med Implants. 2014; 24(1):65-76.
Score: 0.109
-
Tribolayer formation in a metal-on-metal (MoM) hip joint: an electrochemical investigation. J Mech Behav Biomed Mater. 2014 Jan; 29:199-212.
Score: 0.106
-
Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: synergistic interactions of wear and corrosion. J Biomed Mater Res B Appl Biomater. 2012 Aug; 100(6):1662-71.
Score: 0.098
-
What is the role of lipopolysaccharide on the tribocorrosive behavior of titanium? J Mech Behav Biomed Mater. 2012 Apr; 8:71-85.
Score: 0.094
-
New insights into wear and biological effects of metal-on-metal bearings. J Bone Joint Surg Am. 2011 May; 93 Suppl 2:76-83.
Score: 0.090
-
Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater. 2021 06; 118:104443.
Score: 0.045
-
In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH. Med Eng Phys. 2018 02; 52:1-9.
Score: 0.036
-
Fretting-corrosion behavior in hip implant modular junctions: The influence of friction energy and pH variation. J Mech Behav Biomed Mater. 2016 09; 62:570-587.
Score: 0.032
-
Intergranular pitting corrosion of CoCrMo biomedical implant alloy. J Biomed Mater Res B Appl Biomater. 2014 May; 102(4):850-9.
Score: 0.027
-
Influence of corrosion on lipopolysaccharide affinity for two different titanium materials. J Prosthet Dent. 2013 Dec; 110(6):462-70.
Score: 0.027
-
Effect of tribolayer formation on corrosion of CoCrMo alloys investigated using scanning electrochemical microscopy. Anal Chem. 2013 Aug 06; 85(15):7159-66.
Score: 0.026
-
Graphitic tribological layers in metal-on-metal hip replacements. Science. 2011 Dec 23; 334(6063):1687-90.
Score: 0.024
-
Electrochemical behavior of titanium in artificial saliva: influence of pH. J Oral Implantol. 2014 Feb; 40(1):3-10.
Score: 0.024
-
Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study. Clin Oral Implants Res. 2012 Sep; 23(9):1055-62.
Score: 0.023
-
The role of lipopolysaccharide on the electrochemical behavior of titanium. J Dent Res. 2011 May; 90(5):613-8.
Score: 0.022