  1. Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements. J Biomed Mater Res B Appl Biomater. 2018 07; 106(5):1672-1685.
    View in: PubMed
    Score: 0.531
  2. Effects of implant material and plate design on tendon function and morphology. Clin Orthop Relat Res. 2006 Apr; 445:81-90.
    View in: PubMed
    Score: 0.241
  3. Nanoscale surface modification by anodic oxidation increased bone ingrowth and reduced fibrous tissue in the porous coating of titanium-alloy femoral hip arthroplasty implants. J Biomed Mater Res B Appl Biomater. 2017 02; 105(2):283-290.
    View in: PubMed
    Score: 0.117
  4. In vivo oxide-induced stress corrosion cracking of Ti-6Al-4V in a neck-stem modular taper: Emergent behavior in a new mechanism of in vivo corrosion. J Biomed Mater Res B Appl Biomater. 2012 Feb; 100(2):584-94.
    View in: PubMed
    Score: 0.089
  5. In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants. J Biomed Mater Res B Appl Biomater. 2009 Jan; 88(1):206-19.
    View in: PubMed
    Score: 0.073
  6. Implantation of the femoral stem into a bed of titanium granules using vibration: a pilot study of a new method for prosthetic fixation in 5 patients followed for up to 15 years. Ups J Med Sci. 2007; 112(2):183-9.
    View in: PubMed
    Score: 0.063
  7. Bone ingrowth through porous titanium granulate around a femoral stem: histological assessment in a six-month canine hemiarthroplasty model. Ups J Med Sci. 2007; 112(2):191-7.
    View in: PubMed
    Score: 0.063
  8. Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions? Clin Orthop Relat Res. 2016 Oct; 474(10):2232-42.
    View in: PubMed
    Score: 0.031
  9. Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am. 2013 May 15; 95(10):865-72.
    View in: PubMed
    Score: 0.025
  10. Can metal levels be used to monitor metal-on-metal hip arthroplasties? J Arthroplasty. 2004 Dec; 19(8 Suppl 3):59-65.
    View in: PubMed
    Score: 0.014