Markus Wimmer to Microscopy, Electron, Scanning

This is a "connection" page, showing publications Markus Wimmer has written about Microscopy, Electron, Scanning.

 
Connection Strength
 
 
 
0.507
 
  1. Fischer A, Weiss S, Wimmer MA. The tribological difference between biomedical steels and CoCrMo-alloys. J Mech Behav Biomed Mater. 2012 May; 9:50-62.
    View in: PubMed
    Score: 0.117
  2. Laurent MP, Pourzal R, Fischer A, Bertin KC, Jacobs JJ, Wimmer MA. In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
    View in: PubMed
    Score: 0.110
  3. Kaddick C, Wimmer MA. Hip simulator wear testing according to the newly introduced standard ISO 14242. Proc Inst Mech Eng H. 2001; 215(5):429-42.
    View in: PubMed
    Score: 0.054
  4. Wimmer MA, Andriacchi TP, Natarajan RN, Loos J, Karlhuber M, Petermann J, Schneider E, Rosenberg AG. A striated pattern of wear in ultrahigh-molecular-weight polyethylene components of Miller-Galante total knee arthroplasty. J Arthroplasty. 1998 Jan; 13(1):8-16.
    View in: PubMed
    Score: 0.044
  5. Panigrahi P, Liao Y, Mathew MT, Fischer A, Wimmer MA, Jacobs JJ, Marks LD. Intergranular pitting corrosion of CoCrMo biomedical implant alloy. J Biomed Mater Res B Appl Biomater. 2014 May; 102(4):850-9.
    View in: PubMed
    Score: 0.033
  6. Liao Y, Pourzal R, Stemmer P, Wimmer MA, Jacobs JJ, Fischer A, Marks LD. New insights into hard phases of CoCrMo metal-on-metal hip replacements. J Mech Behav Biomed Mater. 2012 Aug; 12:39-49.
    View in: PubMed
    Score: 0.030
  7. Abey S, Mathew MT, Lee DJ, Knoernschild KL, Wimmer MA, Sukotjo C. Electrochemical behavior of titanium in artificial saliva: influence of pH. J Oral Implantol. 2014 Feb; 40(1):3-10.
    View in: PubMed
    Score: 0.029
  8. Barão VA, Mathew MT, Assunção WG, Yuan JC, Wimmer MA, Sukotjo C. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study. Clin Oral Implants Res. 2012 Sep; 23(9):1055-62.
    View in: PubMed
    Score: 0.028
  9. Braunstein V, Sprecher CM, Wimmer MA, Milz S, Taeger G. Influence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints. Acta Orthop. 2009 Jun; 80(3):283-90.
    View in: PubMed
    Score: 0.024
  10. Pennekamp PH, Gessmann J, Diedrich O, Burian B, Wimmer MA, Frauchiger VM, Kraft CN. Short-term microvascular response of striated muscle to cp-Ti, Ti-6Al-4V, and Ti-6Al-7Nb. J Orthop Res. 2006 Mar; 24(3):531-40.
    View in: PubMed
    Score: 0.019
  11. Büscher R, Täger G, Dudzinski W, Gleising B, Wimmer MA, Fischer A. Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation. J Biomed Mater Res B Appl Biomater. 2005 Jan 15; 72(1):206-14.
    View in: PubMed
    Score: 0.018
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.