Markus Wimmer to Knee Prosthesis

This is a "connection" page, showing publications Markus Wimmer has written about Knee Prosthesis.

 
Connection Strength
 
 
 
5.379
 
  1. Pourzal R, Cip J, Rad E, Laurent MP, Berger RA, Jacobs JJ, Wimmer MA. Joint line elevation and tibial slope are associated with increased polyethylene wear in cruciate-retaining total knee replacement. J Orthop Res. 2020 07; 38(7):1596-1606.
    View in: PubMed
    Score: 0.659
  2. Ngai V, Kunze J, Cip J, Laurent MP, Jacobs JJ, Wimmer MA. Backside wear of tibial polyethylene components is affected by gait pattern: A knee simulator study using rare earth tracer technology. J Orthop Res. 2020 07; 38(7):1607-1616.
    View in: PubMed
    Score: 0.659
  3. Knowlton CB, Bhutani P, Wimmer MA. Relationship of surface damage appearance and volumetric wear in retrieved TKR polyethylene liners. J Biomed Mater Res B Appl Biomater. 2017 10; 105(7):2053-2059.
    View in: PubMed
    Score: 0.504
  4. Ngai V, Wimmer MA. Variability of TKR knee kinematics and relationship with gait kinetics: implications for total knee wear. Biomed Res Int. 2015; 2015:284513.
    View in: PubMed
    Score: 0.460
  5. Wimmer MA, Laurent MP, Haman JD, Jacobs JJ, Galante JO. Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res. 2012 Jul; 470(7):1814-25.
    View in: PubMed
    Score: 0.381
  6. Lundberg HJ, Ngai V, Wimmer MA. Comparison of ISO standard and TKR patient axial force profiles during the stance phase of gait. Proc Inst Mech Eng H. 2012 Mar; 226(3):227-34.
    View in: PubMed
    Score: 0.372
  7. Lundberg HJ, Foucher KC, Andriacchi TP, Wimmer MA. Direct comparison of measured and calculated total knee replacement force envelopes during walking in the presence of normal and abnormal gait patterns. J Biomech. 2012 Apr 05; 45(6):990-6.
    View in: PubMed
    Score: 0.370
  8. Ngai V, Schwenke T, Wimmer MA. In-vivo kinematics of knee prostheses patients during level walking compared with the ISO force-controlled simulator standard. Proc Inst Mech Eng H. 2009 Oct; 223(7):889-96.
    View in: PubMed
    Score: 0.315
  9. Ngai V, Wimmer MA. Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: a comparison with the displacement-controlled ISO standard. J Biomech. 2009 Oct 16; 42(14):2363-8.
    View in: PubMed
    Score: 0.312
  10. Mell SP, Wimmer MA, Lundberg HJ. Sensitivity of total knee replacement wear to variability in motion and load input: A parametric finite element analysis study. J Orthop Res. 2020 07; 38(7):1538-1549.
    View in: PubMed
    Score: 0.165
  11. Knowlton CB, Lundberg HJ, Wimmer MA, Jacobs JJ. Can a gait-dependent model predict wear on retrieved total knee arthroplasty components? Bone Joint J. 2020 Jun; 102-B(6_Supple_A):129-137.
    View in: PubMed
    Score: 0.165
  12. Mell SP, Wimmer MA, Lundberg HJ. The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3. J Biomech. 2019 May 09; 88:104-112.
    View in: PubMed
    Score: 0.152
  13. Wimmer MA, Andriacchi TP, Natarajan RN, Loos J, Karlhuber M, Petermann J, Schneider E, Rosenberg AG. A striated pattern of wear in ultrahigh-molecular-weight polyethylene components of Miller-Galante total knee arthroplasty. J Arthroplasty. 1998 Jan; 13(1):8-16.
    View in: PubMed
    Score: 0.140
  14. Wimmer MA, Andriacchi TP. Tractive forces during rolling motion of the knee: implications for wear in total knee replacement. J Biomech. 1997 Feb; 30(2):131-7.
    View in: PubMed
    Score: 0.131
  15. Lundberg HJ, Swanson A, Knowlton C, Inoue N, Wimmer MA. Methods for locating the tibio-femoral contact pathway in total knee replacements using marker-based gait analysis and standard radiography. Iowa Orthop J. 2014; 34:94-101.
    View in: PubMed
    Score: 0.106
  16. Gallo J, Goodman SB, Konttinen YT, Wimmer MA, Holinka M. Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms. Acta Biomater. 2013 Sep; 9(9):8046-58.
    View in: PubMed
    Score: 0.101
  17. Willmann G, Richter H, Wimmer M. [Rotational bending test of hydroxylapatite plasma-coated models of TiAl6V4]. Biomed Tech (Berl). 1993 Jan-Feb; 38(1-2):14-6.
    View in: PubMed
    Score: 0.099
  18. Lundberg HJ, Foucher KC, Wimmer MA. A parametric approach to numerical modeling of TKR contact forces. J Biomech. 2009 Mar 11; 42(4):541-5.
    View in: PubMed
    Score: 0.075
  19. Crowninshield RD, Wimmer MA, Jacobs JJ, Rosenberg AG. Clinical performance of contemporary tibial polyethylene components. J Arthroplasty. 2006 Aug; 21(5):754-61.
    View in: PubMed
    Score: 0.063
  20. Schwenke T, Kaddick C, Schneider E, Wimmer MA. Fluid composition impacts standardized testing protocols in ultrahigh molecular weight polyethylene knee wear testing. Proc Inst Mech Eng H. 2005 Nov; 219(6):457-64.
    View in: PubMed
    Score: 0.060
  21. Rastogi S, Kurelec L, Lippits D, Cuijpers J, Wimmer M, Lemstra PJ. Novel route to fatigue-resistant fully sintered ultrahigh molecular weight polyethylene for knee prosthesis. Biomacromolecules. 2005 Mar-Apr; 6(2):942-7.
    View in: PubMed
    Score: 0.057
  22. Freed RD, Simon JC, Knowlton CB, Orozco VillaseƱor DA, Wimmer MA, Lundberg HJ. Are Instrumented Knee Forces Representative of a Larger Population of Cruciate-Retaining Total Knee Arthroplasties? J Arthroplasty. 2017 07; 32(7):2268-2273.
    View in: PubMed
    Score: 0.033
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.