Markus Wimmer to Knee Joint
This is a "connection" page, showing publications Markus Wimmer has written about Knee Joint.
Connection Strength
4.575
-
Level and Downhill Walking to Assess Implant Functionality in Bicruciate- and Posterior Cruciate-Retaining Total Knee Arthroplasty. J Arthroplasty. 2018 09; 33(9):2884-2889.
Score: 0.399
-
How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study. Clin Orthop Relat Res. 2016 Aug; 474(8):1867-75.
Score: 0.342
-
The Feasibility of Using Augmented Auditory Feedback From a Pressure Detecting Insole to Reduce the Knee Adduction Moment: A Proof of Concept Study. J Biomech Eng. 2016 Feb; 138(2):021014.
Score: 0.341
-
Comparison of Antagonist Muscle Activity During Walking Between Total Knee Replacement and Control Subjects Using Unnormalized Electromyography. J Arthroplasty. 2016 06; 31(6):1331-1339.
Score: 0.338
-
Methods for locating the tibio-femoral contact pathway in total knee replacements using marker-based gait analysis and standard radiography. Iowa Orthop J. 2014; 34:94-101.
Score: 0.295
-
Does hip implant positioning affect the peak external adduction moments of the healthy knees of subjects with total hip replacements? J Orthop Res. 2013 Aug; 31(8):1187-94.
Score: 0.280
-
Direct comparison of measured and calculated total knee replacement force envelopes during walking in the presence of normal and abnormal gait patterns. J Biomech. 2012 Apr 05; 45(6):990-6.
Score: 0.258
-
Contralateral hip and knee gait biomechanics are unchanged by total hip replacement for unilateral hip osteoarthritis. Gait Posture. 2012 Jan; 35(1):61-5.
Score: 0.251
-
In-vivo kinematics of knee prostheses patients during level walking compared with the ISO force-controlled simulator standard. Proc Inst Mech Eng H. 2009 Oct; 223(7):889-96.
Score: 0.220
-
Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: a comparison with the displacement-controlled ISO standard. J Biomech. 2009 Oct 16; 42(14):2363-8.
Score: 0.217
-
A parametric approach to numerical modeling of TKR contact forces. J Biomech. 2009 Mar 11; 42(4):541-5.
Score: 0.210
-
Knee joint loading differs in individuals with mild compared with moderate medial knee osteoarthritis. Arthritis Rheum. 2006 Dec; 54(12):3842-9.
Score: 0.181
-
Sensitivity of total knee replacement wear to variability in motion and load input: A parametric finite element analysis study. J Orthop Res. 2020 07; 38(7):1538-1549.
Score: 0.115
-
Expanding instrumented gait testing in the community setting: A portable, depth-sensing camera captures joint motion in older adults. PLoS One. 2019; 14(5):e0215995.
Score: 0.107
-
A striated pattern of wear in ultrahigh-molecular-weight polyethylene components of Miller-Galante total knee arthroplasty. J Arthroplasty. 1998 Jan; 13(1):8-16.
Score: 0.097
-
Are Instrumented Knee Forces Representative of a Larger Population of Cruciate-Retaining Total Knee Arthroplasties? J Arthroplasty. 2017 07; 32(7):2268-2273.
Score: 0.092
-
Tractive forces during rolling motion of the knee: implications for wear in total knee replacement. J Biomech. 1997 Feb; 30(2):131-7.
Score: 0.091
-
From normal to fast walking: Impact of cadence and stride length on lower extremity joint moments. Gait Posture. 2016 05; 46:118-25.
Score: 0.085
-
Asymmetries and relationships between dynamic loading, muscle strength, and proprioceptive acuity at the knees in symptomatic unilateral hip osteoarthritis. Arthritis Res Ther. 2014 Dec 14; 16(6):455.
Score: 0.079
-
Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms. Acta Biomater. 2013 Sep; 9(9):8046-58.
Score: 0.071
-
Improvement in knee loading after use of specialized footwear for knee osteoarthritis: results of a six-month pilot investigation. Arthritis Rheum. 2013 May; 65(5):1282-9.
Score: 0.070
-
The relationship of vibratory perception to dynamic joint loading, radiographic severity, and pain in knee osteoarthritis. Arthritis Rheum. 2012 Jan; 64(1):181-6.
Score: 0.064
-
Asymmetric loading and bone mineral density at the asymptomatic knees of patients with unilateral hip osteoarthritis. Arthritis Rheum. 2011 Dec; 63(12):3853-8.
Score: 0.064
-
Effects of common footwear on joint loading in osteoarthritis of the knee. Arthritis Care Res (Hoboken). 2010 Jul; 62(7):917-23.
Score: 0.058
-
Surface topography of viable articular cartilage measured with scanning white light interferometry. Osteoarthritis Cartilage. 2009 Sep; 17(9):1197-203.
Score: 0.053
-
Relationship between pain and medial knee joint loading in mild radiographic knee osteoarthritis. Arthritis Rheum. 2007 Oct 15; 57(7):1254-60.
Score: 0.048
-
ACL transection results in a posterior shift and increased velocity of contact on the medial tibial plateau. J Biomech. 2022 11; 144:111335.
Score: 0.034
-
The effect of albumin and ?-globulin on synovial fluid lubrication: Implication for knee joint replacements. J Mech Behav Biomed Mater. 2021 01; 113:104117.
Score: 0.029
-
The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3. J Biomech. 2019 May 09; 88:104-112.
Score: 0.027
-
Gait asymmetries in unilateral symptomatic hip osteoarthritis and their association with radiographic severity and pain. Hip Int. 2019 Mar; 29(2):209-214.
Score: 0.025
-
Hamstring Activity in the Anterior Cruciate Ligament Injured Patient: Injury Implications and Comparison With Quadriceps Activity. Arthroscopy. 2016 08; 32(8):1651-9.
Score: 0.022
-
Bone mineral density in the proximal tibia varies as a function of static alignment and knee adduction angular momentum in individuals with medial knee osteoarthritis. Bone. 2006 Nov; 39(5):1116-1122.
Score: 0.011