Profiles

Keywords
Last Name
Institution

Hannah Jean Lundberg

TitleAssociate Professor
InstitutionRush University, Rush Medical College
DepartmentOrthopedic Surgery
Address1611 W. Harrison St.
Chicago IL 60612
Phone312-942-1445
Fax312-942-4491
vCardDownload vCard

    Collapse Overview 
    Collapse overview
    My specific areas of research involve investigating the biomechanical function of human joints (natural and implanted) using computer modeling. Current emphases include predicting total knee replacement forces and behavior during everyday life, wear of total knee replacements, and biomechanical behavior of total hip replacement modular taper junctions.

    My ORCID is 0000-0002-6981-8690.
    My Scopus ID is 8571339300.
    My NIH COMMONS name is HLUNDBERG.

    Education: PhD, Biomedical Engineering, University of Iowa


    Collapse Bibliographic 
    Collapse selected publications
    Publications listed below are automatically derived from MEDLINE/PubMed and other sources, which might result in incorrect or missing publications. Faculty can login to make corrections and additions.
    List All   |   Timeline
    1. Godoy M, Gustafson JA, Hertzler JS, Bischoff JE, Pourzal R, Lundberg HJ. Model validation for estimating taper microgroove deformation during total hip arthroplasty head-neck assembly. J Biomech. 2022 07; 140:111172. PMID: 35696772.
      View in: PubMed
    2. Gustafson JA, Mell SP, Levine BR, Pourzal R, Lundberg HJ. Interaction of surface topography and taper mismatch on head-stem modular junction contact mechanics during assembly in modern total hip replacement. J Orthop Res. 2023 02; 41(2):418-425. PMID: 35488727.
      View in: PubMed
    3. Mell SP, Wimmer MA, Jacobs JJ, Lundberg HJ. Optimal surgical component alignment minimizes TKR wear - An in silico study with nine alignment parameters. J Mech Behav Biomed Mater. 2022 01; 125:104939. PMID: 34740015.
      View in: PubMed
    4. McCarthy SM, Hall DJ, Mathew MT, Jacobs JJ, Lundberg HJ, Pourzal R. Are Damage Modes Related to Microstructure and Material Loss in Severely Damaged CoCrMo Femoral Heads? Clin Orthop Relat Res. 2021 09 01; 479(9):2083-2096. PMID: 34019490.
      View in: PubMed
    5. Gustafson JA, Pourzal R, Levine BR, Jacobs JJ, Lundberg HJ. Corrigenda. Bone Joint J. 2021 Aug; 103-B(8):1438. PMID: 34334052.
      View in: PubMed
    6. Royhman D, Pourzal R, Hall D, Lundberg HJ, Wimmer MA, Jacobs J, Hallab NJ, Mathew MT. Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater. 2021 06; 118:104443. PMID: 33752094.
      View in: PubMed
    7. Mallow GM, Siyaji ZK, Galbusera F, Espinoza-Or?as AA, Giers M, Lundberg H, Ames C, Karppinen J, Louie PK, Phillips FM, Pourzal R, Schwab J, Sciubba DM, Wang JC, Wilke HJ, Williams FMK, Mohiuddin SA, Makhni MC, Shepard NA, An HS, Samartzis D. Intelligence-Based Spine Care Model: A New Era of Research and Clinical Decision-Making. Global Spine J. 2021 Mar; 11(2):135-145. PMID: 33251858.
      View in: PubMed
    8. Gustafson JA, Pourzal R, Levine BR, Jacobs JJ, Lundberg HJ. Modelling changes in modular taper micromechanics due to surgeon assembly technique in total hip arthroplasty. Bone Joint J. 2020 Jul; 102-B(7_Supple_B):33-40. PMID: 32600210.
      View in: PubMed
    9. Mell SP, Wimmer MA, Lundberg HJ. Sensitivity of total knee replacement wear to variability in motion and load input: A parametric finite element analysis study. J Orthop Res. 2020 07; 38(7):1538-1549. PMID: 32458460.
      View in: PubMed
    10. Knowlton CB, Lundberg HJ, Wimmer MA, Jacobs JJ. Can a gait-dependent model predict wear on retrieved total knee arthroplasty components? Bone Joint J. 2020 Jun; 102-B(6_Supple_A):129-137. PMID: 32475284.
      View in: PubMed
    11. Bechstedt M, Gustafson JA, Mell SP, G?hrs J, Morlock MM, Levine BR, Lundberg HJ. Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers. J Biomech. 2020 04 16; 103:109689. PMID: 32139099.
      View in: PubMed
    12. Mell SP, Wimmer MA, Lundberg HJ. The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3. J Biomech. 2019 May 09; 88:104-112. PMID: 30940359.
      View in: PubMed
    13. Mell SP, Fullam S, Wimmer MA, Lundberg HJ. Finite element evaluation of the newest ISO testing standard for polyethylene total knee replacement liners. Proc Inst Mech Eng H. 2018 Jun; 232(6):545-552. PMID: 29658386.
      View in: PubMed
    14. Pourzal R, Lundberg HJ, Hall DJ, Jacobs JJ. What Factors Drive Taper Corrosion? J Arthroplasty. 2018 09; 33(9):2707-2711. PMID: 29705684.
      View in: PubMed
    15. Hall DJ, Pourzal R, Lundberg HJ, Mathew MT, Jacobs JJ, Urban RM. Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements. J Biomed Mater Res B Appl Biomater. 2018 07; 106(5):1672-1685. PMID: 28842959.
      View in: PubMed
    16. Freed RD, Simon JC, Knowlton CB, Orozco Villase?or DA, Wimmer MA, Lundberg HJ. Are Instrumented Knee Forces Representative of a Larger Population of Cruciate-Retaining Total Knee Arthroplasties? J Arthroplasty. 2017 07; 32(7):2268-2273. PMID: 28262455.
      View in: PubMed
    17. Pourzal R, Hall DJ, Ha NQ, Urban RM, Levine BR, Jacobs JJ, Lundberg HJ. Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions? Clin Orthop Relat Res. 2016 Oct; 474(10):2232-42. PMID: 27339123.
      View in: PubMed
    18. Ferrigno C, Wimmer MA, Trombley RM, Lundberg HJ, Shakoor N, Thorp LE. A reduction in the knee adduction moment with medial thrust gait is associated with a medial shift in center of plantar pressure. Med Eng Phys. 2016 07; 38(7):615-621. PMID: 27158051.
      View in: PubMed
    19. Frank RM, Lundberg H, Wimmer MA, Forsythe B, Bach BR, Verma NN, Cole BJ. Hamstring Activity in the Anterior Cruciate Ligament Injured Patient: Injury Implications and Comparison With Quadriceps Activity. Arthroscopy. 2016 08; 32(8):1651-9. PMID: 27067475.
      View in: PubMed
    20. Lundberg HJ, Rojas IL, Foucher KC, Wimmer MA. Comparison of Antagonist Muscle Activity During Walking Between Total Knee Replacement and Control Subjects Using Unnormalized Electromyography. J Arthroplasty. 2016 06; 31(6):1331-1339. PMID: 26763897.
      View in: PubMed
    21. Mathew MT, Kerwell S, Lundberg HJ, Sukotjo C, Mercuri LG. Tribocorrosion and oral and maxillofacial surgical devices. Br J Oral Maxillofac Surg. 2014 May; 52(5):396-400. PMID: 24630987.
      View in: PubMed
    22. Lundberg HJ, Swanson A, Knowlton C, Inoue N, Wimmer MA. Methods for locating the tibio-femoral contact pathway in total knee replacements using marker-based gait analysis and standard radiography. Iowa Orthop J. 2014; 34:94-101. PMID: 25328466.
      View in: PubMed
    23. Lundberg HJ, Wimmer MA. Computational Framework for Determining Patient-Specific Total Knee Arthroplasty Loading. J Med Device. 2013 Dec; 7(4):0409041-409041. PMID: 24895516.
      View in: PubMed
    24. Lundberg HJ, Knowlton C, Wimmer MA. Fine tuning total knee replacement contact force prediction algorithms using blinded model validation. J Biomech Eng. 2013 Feb; 135(2):021015. PMID: 23445060.
      View in: PubMed
    25. Lundberg HJ, Ngai V, Wimmer MA. Comparison of ISO standard and TKR patient axial force profiles during the stance phase of gait. Proc Inst Mech Eng H. 2012 Mar; 226(3):227-34. PMID: 22558837.
      View in: PubMed
    26. Lundberg HJ, Foucher KC, Andriacchi TP, Wimmer MA. Direct comparison of measured and calculated total knee replacement force envelopes during walking in the presence of normal and abnormal gait patterns. J Biomech. 2012 Apr 05; 45(6):990-6. PMID: 22284431.
      View in: PubMed
    27. Brown TD, Lundberg HJ, Pedersen DR, Callaghan JJ. 2009 Nicolas Andry Award: clinical biomechanics of third body acceleration of total hip wear. Clin Orthop Relat Res. 2009 Jul; 467(7):1885-97. PMID: 19399565.
      View in: PubMed
    28. Lundberg HJ, Foucher KC, Wimmer MA. A parametric approach to numerical modeling of TKR contact forces. J Biomech. 2009 Mar 11; 42(4):541-5. PMID: 19155015.
      View in: PubMed
    29. Heiner AD, Lundberg HJ, Baer TE, Pedersen DR, Callaghan JJ, Brown TD. Effects of episodic subluxation events on third body ingress and embedment in the THA bearing surface. J Biomech. 2008 Jul 19; 41(10):2090-6. PMID: 18561936.
      View in: PubMed
    30. Lundberg HJ, Liu SS, Callaghan JJ, Pedersen DR, O'Rourke MR, Goetz DD, Vittetoe DA, Clohisy JC, Brown TD. Association of third body embedment with rim damage in retrieved acetabular liners. Clin Orthop Relat Res. 2007 Dec; 465:133-9. PMID: 18090471.
      View in: PubMed
    31. Lundberg HJ, Pedersen DR, Baer TE, Muste M, Callaghan JJ, Brown TD. Effects of implant design parameters on fluid convection, potentiating third-body debris ingress into the bearing surface during THA impingement/subluxation. J Biomech. 2007; 40(8):1676-85. PMID: 17400230.
      View in: PubMed
    32. Troy KL, Lundberg HJ, Conzemius MG, Brown TD. Habitual hip joint activity level of the penned EMU (Dromaius novaehollandie). Iowa Orthop J. 2007; 27:17-23. PMID: 17907425.
      View in: PubMed
    33. Lundberg HJ, Stewart KJ, Pedersen DR, Callaghan JJ, Brown TD. Nonidentical and outlier duty cycles as factors accelerating UHMWPE wear in THA: a finite element exploration. J Orthop Res. 2007 Jan; 25(1):30-43. PMID: 17019701.
      View in: PubMed
    34. Lundberg HJ, Stewart KJ, Pedersen DR, Callaghan JJ, Brown TD. Problematic sites of third body embedment in polyethylene for total hip wear acceleration. J Biomech. 2006; 39(7):1208-16. PMID: 15894322.
      View in: PubMed
    35. Lundberg HJ, Stewart KJ, Callaghan JJ, Brown TD. Kinetically critical sites of femoral head roughening for wear rate acceleration in total hip arthroplasty. Clin Orthop Relat Res. 2005 Jan; (430):89-93. PMID: 15662308.
      View in: PubMed
    36. El-Khoury GY, Alliman KJ, Lundberg HJ, Rudert MJ, Brown TD, Saltzman CL. Cartilage thickness in cadaveric ankles: measurement with double-contrast multi-detector row CT arthrography versus MR imaging. Radiology. 2004 Dec; 233(3):768-73. PMID: 15516604.
      View in: PubMed
    Lundberg's Networks
    Click the "See All" links for more information and interactive visualizations!
    Concepts Expand Description
    _
    Co-Authors Expand Description
    _
    Similar People Expand Description
    _
    Same Department Expand Description
    Physical Neighbors Expand Description
    _