Joshua Jacobs to Humans
This is a "connection" page, showing publications Joshua Jacobs has written about Humans.
Connection Strength
2.036
-
Risk Stratification Algorithm for Management of Head-Neck Taper Tribocorrosion in Patients with Metal-on-Polyethylene Total Hip Arthroplasty: Consensus Statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and The Hip Society. J Bone Joint Surg Am. 2021 03 03; 103(5):e18.
Score: 0.042
-
Augmented Reality in Orthopedic Practice and Education. Orthop Clin North Am. 2021 Jan; 52(1):15-26.
Score: 0.042
-
Can a gait-dependent model predict wear on retrieved total knee arthroplasty components? Bone Joint J. 2020 Jun; 102-B(6_Supple_A):129-137.
Score: 0.040
-
Adverse Local Tissue Reaction due to Mechanically Assisted Crevice Corrosion Presenting as Late Instability Following Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty. 2020 09; 35(9):2666-2670.
Score: 0.040
-
What Surgeons Need to Know About Adverse Local Tissue Reaction in Total Hip Arthroplasty. J Arthroplasty. 2020 06; 35(6S):S55-S59.
Score: 0.039
-
Addressing Disparities in Total Hip Replacement Outcomes: Commentary on an article by Kanu Okike, MD, MPH, et al.: "Association of Race and Ethnicity with Total Hip Arthroplasty Outcomes in a Universally Insured Population". J Bone Joint Surg Am. 2019 07 03; 101(13):e66.
Score: 0.038
-
What Factors Drive Taper Corrosion? J Arthroplasty. 2018 09; 33(9):2707-2711.
Score: 0.034
-
Diagnosing Taper Corrosion: When Is It the Taper and When Is It Something Else? J Arthroplasty. 2018 09; 33(9):2712-2715.
Score: 0.034
-
Serum Metal Levels for Diagnosis of Adverse Local Tissue Reactions?Secondary to Corrosion in Metal-on-Polyethylene Total?Hip?Arthroplasty. J Arthroplasty. 2017 09; 32(9S):S272-S277.
Score: 0.032
-
Serum Metal Concentrations in Patients With Titanium Ceramic Composite Cervical Disc Replacements. Spine (Phila Pa 1976). 2017 Mar 15; 42(6):366-371.
Score: 0.032
-
Corrosion at the Head-Neck Junction: Why Is This Happening Now? J Arthroplasty. 2016 07; 31(7):1378-80.
Score: 0.030
-
Metal Hypersensitivity and Total Knee Arthroplasty. J Am Acad Orthop Surg. 2016 Feb; 24(2):106-12.
Score: 0.030
-
Reply to letter to the editor: do complication rates differ by gender after metal-on-metal hip resurfacing arthroplasty? A systematic review. Clin Orthop Relat Res. 2015 Dec; 473(12):3983-4.
Score: 0.029
-
Do Complication Rates Differ by Gender After Metal-on-metal Hip Resurfacing Arthroplasty? A Systematic Review. Clin Orthop Relat Res. 2015 Aug; 473(8):2521-9.
Score: 0.029
-
Do retrieval analysis and blood metal measurements contribute to our understanding of adverse local tissue reactions? Clin Orthop Relat Res. 2014 Dec; 472(12):3718-27.
Score: 0.027
-
Metal ion levels in maternal and placental blood after metal-on-metal total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2014 Dec; 43(12):E304-8.
Score: 0.027
-
Risk stratification algorithm for management of patients with dual modular taper total hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons and the Hip Society. J Arthroplasty. 2014 Nov; 29(11):2060-4.
Score: 0.027
-
Effect of a second joint arthroplasty on metal ion levels after primary total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2013 Oct; 42(10):E84-7.
Score: 0.025
-
Beyond the decade: strategic priorities to reduce the burden of musculoskeletal disease. J Bone Joint Surg Am. 2013 Sep 04; 95(17):e1251-6.
Score: 0.025
-
Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am. 2013 May 15; 95(10):865-72.
Score: 0.025
-
An important contribution to our understanding of the performance of the current generation of metal-on-metal hip replacements. J Bone Joint Surg Am. 2013 Apr 17; 95(8):e53.
Score: 0.024
-
Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*. J Bone Joint Surg Am. 2013 Mar 20; 95(6):512-8.
Score: 0.024
-
Do ion concentrations after metal-on-metal hip resurfacing increase over time? A prospective study. J Arthroplasty. 2013 Apr; 28(4):695-700.
Score: 0.024
-
Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am. 2012 Sep 19; 94(18):1655-61.
Score: 0.023
-
Asymptomatic prospective and retrospective cohorts with metal-on-metal hip arthroplasty indicate acquired lymphocyte reactivity varies with metal ion levels on a group basis. J Orthop Res. 2013 Feb; 31(2):173-82.
Score: 0.023
-
Commentary: Total disc arthroplasty and the bearing surface debate. Spine J. 2012 Aug; 12(8):702-4.
Score: 0.023
-
Evaluation and treatment of painful total hip arthroplasties with modular metal taper junctions. Orthopedics. 2012 May; 35(5):386-91.
Score: 0.023
-
American Academy of Orthopaedic Surgeons clinical practice guideline on: preventing venous thromboembolic disease in patients undergoing elective hip and knee arthroplasty. J Bone Joint Surg Am. 2012 Apr 18; 94(8):746-7.
Score: 0.023
-
The utility of MARS MRI in patients with metal-on-metal bearings: commentary on an article by Alister J. Hart, MA, MD, FRCSG(Orth), et al.: "Pseudotumors in association with well-functioning metal-on-metal hip prostheses. a case-control study using three-dimensional computed tomography and magnetic resonance imaging". J Bone Joint Surg Am. 2012 Feb 15; 94(4):e26.
Score: 0.022
-
AAOS clinical practice guideline: preventing venous thromboembolic disease in patients undergoing elective hip and knee arthroplasty. J Am Acad Orthop Surg. 2011 Dec; 19(12):777-8.
Score: 0.022
-
In vivo oxide-induced stress corrosion cracking of Ti-6Al-4V in a neck-stem modular taper: Emergent behavior in a new mechanism of in vivo corrosion. J Biomed Mater Res B Appl Biomater. 2012 Feb; 100(2):584-94.
Score: 0.022
-
Commentary on an article by Stephen S. Tower, MD: "Arthroprosthetic cobaltism: neurological and cardiac manifestations in two patients with metal-on-metal arthroplasty. a case report". J Bone Joint Surg Am. 2010 Dec 01; 92(17):e35.
Score: 0.021
-
Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am. 2010 Jun; 92(6):1518-21.
Score: 0.020
-
Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res. 2010 Apr; 28(4):436-43.
Score: 0.020
-
In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation. J Biomed Mater Res A. 2010 Feb; 92(2):667-82.
Score: 0.020
-
Biologic activity of wear particles. Instr Course Lect. 2010; 59:3-16.
Score: 0.019
-
US bone and joint decade prepares for the future. Arthritis Rheum. 2009 Nov 15; 61(11):1470-1.
Score: 0.019
-
Role of technology assessment in orthopaedics. Clin Orthop Relat Res. 2009 Oct; 467(10):2570-6.
Score: 0.019
-
Metal-on-metal bearing surfaces. J Am Acad Orthop Surg. 2009 Feb; 17(2):69-76.
Score: 0.018
-
Biologic effects of implant debris. Bull NYU Hosp Jt Dis. 2009; 67(2):182-8.
Score: 0.018
-
Translational research: Whither the ORS? J Orthop Res. 2008 May; 26(5):737-40.
Score: 0.017
-
Technology assessment and adoption in orthopaedics: lessons learned. J Bone Joint Surg Am. 2008 Apr; 90(4):689-90.
Score: 0.017
-
How has the biologic reaction to wear particles changed with newer bearing surfaces? J Am Acad Orthop Surg. 2008; 16 Suppl 1:S49-55.
Score: 0.017
-
Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
Score: 0.017
-
Tribology: a portal to understand joint failure? Arthritis Rheum. 2007 Nov; 56(11):3511-3.
Score: 0.017
-
Trends in joint arthroplasty: minimally invasive surgery, wear-resistant materials, and biologics. J Clin Rheumatol. 2007 Jun; 13(3):153-8.
Score: 0.016
-
Closing the gap: Orthopaedic research in clinical practice. J Am Acad Orthop Surg. 2007 Jan; 15(1):1-2.
Score: 0.016
-
Applications of porous tantalum in total hip arthroplasty. J Am Acad Orthop Surg. 2006 Nov; 14(12):646-55.
Score: 0.016
-
Serum metal levels and bearing surfaces in total hip arthroplasty. J Arthroplasty. 2006 Sep; 21(6 Suppl 2):47-52.
Score: 0.015
-
Relationships with industry: critical for new technology or an unnecessary evil? J Bone Joint Surg Am. 2006 Jul; 88(7):1650-63.
Score: 0.015
-
Experimental and clinical performance of porous tantalum in orthopedic surgery. Biomaterials. 2006 Sep; 27(27):4671-81.
Score: 0.015
-
Loosening and osteolysis associated with metal-on-metal bearings: A local effect of metal hypersensitivity? J Bone Joint Surg Am. 2006 Jun; 88(6):1171-2.
Score: 0.015
-
Wear particles. J Bone Joint Surg Am. 2006 Apr; 88 Suppl 2:99-102.
Score: 0.015
-
Effects of soluble metals on human peri-implant cells. J Biomed Mater Res A. 2005 Jul 01; 74(1):124-40.
Score: 0.014
-
Lymphocyte responses in patients with total hip arthroplasty. J Orthop Res. 2005 Mar; 23(2):384-91.
Score: 0.014
-
The biology of alternative bearing surfaces in total joint arthroplasty. Instr Course Lect. 2005; 54:481-93.
Score: 0.014
-
A consensus paper on metal ions in metal-on-metal hip arthroplasties. J Arthroplasty. 2004 Dec; 19(8 Suppl 3):12-6.
Score: 0.014
-
Can metal levels be used to monitor metal-on-metal hip arthroplasties? J Arthroplasty. 2004 Dec; 19(8 Suppl 3):59-65.
Score: 0.014
-
Immune responses correlate with serum-metal in metal-on-metal hip arthroplasty. J Arthroplasty. 2004 Dec; 19(8 Suppl 3):88-93.
Score: 0.014
-
Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty. J Arthroplasty. 2004 Dec; 19(8 Suppl 3):94-101.
Score: 0.014
-
Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements. J Orthop Res. 2004 Mar; 22(2):250-9.
Score: 0.013
-
Metal degradation products: a cause for concern in metal-metal bearings? Clin Orthop Relat Res. 2003 Dec; (417):139-47.
Score: 0.013
-
Spinal implant debris-induced osteolysis. Spine (Phila Pa 1976). 2003 Oct 15; 28(20):S125-38.
Score: 0.013
-
Interfacial kinetics of titanium- and cobalt-based implant alloys in human serum: metal release and biofilm formation. J Biomed Mater Res A. 2003 Jun 01; 65(3):311-8.
Score: 0.012
-
Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty. J Bone Joint Surg Am. 2003 Jun; 85(6):1111-7.
Score: 0.012
-
Has Wrought Cobalt-Chromium-Molybdenum Alloy Changed for the Worse Over Time? J Arthroplasty. 2023 07; 38(7S):S280-S284.
Score: 0.012
-
Non-ischaemic cardiomyopathy associated with elevated serum cobalt and accelerated wear of a metal-on-metal hip resurfacing. BMJ Case Rep. 2022 Jun 27; 15(6).
Score: 0.012
-
Concentration- and composition-dependent effects of metal ions on human MG-63 osteoblasts. J Biomed Mater Res. 2002 Jun 05; 60(3):420-33.
Score: 0.011
-
A question of prevalence: liner dislodgment in Harris-Galante acetabular components. J Bone Joint Surg Am. 2002 Jan; 84(1):143-4.
Score: 0.011
-
Optimal surgical component alignment minimizes TKR wear - An in silico study with nine alignment parameters. J Mech Behav Biomed Mater. 2022 01; 125:104939.
Score: 0.011
-
Are Damage Modes Related to Microstructure and Material Loss in Severely Damaged CoCrMo Femoral Heads? Clin Orthop Relat Res. 2021 09 01; 479(9):2083-2096.
Score: 0.011
-
COVID-19 (SARS-CoV-2) lymphocyte responses are associated with inflammatory biomarkers in total joint replacement surgery candidates pre-operatively. J Orthop Surg Res. 2021 Jun 30; 16(1):415.
Score: 0.011
-
Early outcomes of a modern cemented total knee arthroplasty : is tibial loosening a concern? Bone Joint J. 2021 Jun; 103-B(6 Supple A):51-58.
Score: 0.011
-
Metal-induced delayed type hypersensitivity responses potentiate particle induced osteolysis in a sex and age dependent manner. PLoS One. 2021; 16(5):e0251885.
Score: 0.011
-
Comparison of Bone Turnover Biomarkers in Serum and Urine Measured on an Automated Analytical Platform. J Appl Lab Med. 2021 04 29; 6(3):750-755.
Score: 0.011
-
Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater. 2021 06; 118:104443.
Score: 0.011
-
Modelling changes in modular taper micromechanics due to surgeon assembly technique in total hip arthroplasty. Bone Joint J. 2020 Jul; 102-B(7_Supple_B):33-40.
Score: 0.010
-
Echocardiographic Changes in the Context of Metal-on-Metal Versus Nonmetal-on-Metal Total Hip Arthroplasty. J Arthroplasty. 2020 11; 35(11):3230-3236.e3.
Score: 0.010
-
The American Board of Orthopaedic Surgery Response to COVID-19. J Am Acad Orthop Surg. 2020 Jun 01; 28(11):e465-e468.
Score: 0.010
-
Joint line elevation and tibial slope are associated with increased polyethylene wear in cruciate-retaining total knee replacement. J Orthop Res. 2020 07; 38(7):1596-1606.
Score: 0.010
-
Backside wear of tibial polyethylene components is affected by gait pattern: A knee simulator study using rare earth tracer technology. J Orthop Res. 2020 07; 38(7):1607-1616.
Score: 0.010
-
Do Battlefield Injury-acquired Indwelling Metal Fragments Induce Metal Immunogenicity? Clin Orthop Relat Res. 2020 04; 478(4):752-766.
Score: 0.010
-
Fourier transform infrared spectroscopic imaging of wear and corrosion products within joint capsule tissue from total hip replacements patients. J Biomed Mater Res B Appl Biomater. 2020 02; 108(2):513-526.
Score: 0.009
-
High Failure at a Minimum 5-Year Follow-Up in Primary Total Hip Arthroplasty Using a Modular Femoral Trunnion. J Arthroplasty. 2019 07; 34(7):1395-1399.
Score: 0.009
-
Personality Assessment in Orthopaedic Surgery: AOA Critical Issues. J Bone Joint Surg Am. 2019 Feb 20; 101(4):e13.
Score: 0.009
-
Transition from metal-DTH resistance to susceptibility is facilitated by NLRP3 inflammasome signaling induced Th17 reactivity: Implications for orthopedic implants. PLoS One. 2019; 14(1):e0210336.
Score: 0.009
-
Metal wear particles in hematopoietic marrow of the axial skeleton in patients with prior revision for mechanical failure of a hip or knee arthroplasty. J Biomed Mater Res B Appl Biomater. 2019 08; 107(6):1930-1936.
Score: 0.009
-
Discovery of biomarkers to identify peri-implant osteolysis before radiographic diagnosis. J Orthop Res. 2018 10; 36(10):2754-2761.
Score: 0.009
-
Regenerative medicine will make orthopaedic implants obsolete in our time Orthopaedic Research Society first annual meeting debate, San Diego, March 21st, 2017. J Orthop Res. 2018 10; 36(10):2579-2585.
Score: 0.009
-
Risk Adjustment Is Necessary in Medicare Bundled Payment Models for Total Hip and Knee Arthroplasty. J Arthroplasty. 2018 08; 33(8):2368-2375.
Score: 0.009
-
Adverse Local Tissue Reaction After a Metal-on-Metal Total Hip Prosthesis Without Elevated Serum Metal Ion Levels. Orthopedics. 2018 May 01; 41(3):e438-e441.
Score: 0.008
-
Alloy Microstructure Dictates Corrosion Modes in THA Modular Junctions. Clin Orthop Relat Res. 2017 Dec; 475(12):3026-3043.
Score: 0.008
-
Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements. J Biomed Mater Res B Appl Biomater. 2018 07; 106(5):1672-1685.
Score: 0.008
-
Females with Unexplained Joint Pain Following Total Joint Arthroplasty Exhibit a Higher Rate and Severity of Hypersensitivity to Implant Metals Compared with Males: Implications of Sex-Based Bioreactivity Differences. J Bone Joint Surg Am. 2017 Apr 19; 99(8):621-628.
Score: 0.008
-
Aseptic Lymphocytic-Dominated Vasculitis-Associated Lesions Scores Do Not Correlate With Metal Ion Levels or Unreadable Synovial Fluid White Blood Cell Counts. J Arthroplasty. 2017 04; 32(4):1340-1343.
Score: 0.008
-
Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions? Clin Orthop Relat Res. 2016 Oct; 474(10):2232-42.
Score: 0.008
-
Cobalt Alloy Implant Debris Induces Inflammation and Bone Loss Primarily through Danger Signaling, Not TLR4 Activation: Implications for DAMP-ening Implant Related Inflammation. PLoS One. 2016; 11(7):e0160141.
Score: 0.008
-
Repair of Intraoperative Injury to the Medial Collateral Ligament During Primary Total Knee Arthroplasty. J Bone Joint Surg Am. 2016 Jan 06; 98(1):35-9.
Score: 0.007
-
Diagnosis and Management of Adverse Local Tissue Reactions Secondary to Corrosion at the Head-Neck Junction in Patients With Metal on Polyethylene Bearings. J Arthroplasty. 2016 Jan; 31(1):264-8.
Score: 0.007
-
A patient-specific computational model of hypoxia-modulated radiation resistance in glioblastoma using 18F-FMISO-PET. J R Soc Interface. 2015 Feb 06; 12(103).
Score: 0.007
-
Do serologic and synovial tests help diagnose infection in revision hip arthroplasty with metal-on-metal bearings or corrosion? Clin Orthop Relat Res. 2015 Feb; 473(2):498-505.
Score: 0.007
-
Modern trunnions are more flexible: a mechanical analysis of THA taper designs. Clin Orthop Relat Res. 2014 Dec; 472(12):3963-70.
Score: 0.007
-
The pathology of orthopedic implant failure is mediated by innate immune system cytokines. Mediators Inflamm. 2014; 2014:185150.
Score: 0.007
-
Midterm results of a femoral stem with a modular neck design: clinical outcomes and metal ion analysis. J Arthroplasty. 2014 Sep; 29(9):1768-73.
Score: 0.007
-
Risk stratification algorithm for management of patients with metal-on-metal hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and the Hip Society. J Bone Joint Surg Am. 2014 Jan 01; 96(1):e4.
Score: 0.006
-
Implant debris particle size affects serum protein adsorption which may contribute to particle size-based bioreactivity differences. J Long Term Eff Med Implants. 2014; 24(1):77-88.
Score: 0.006
-
Increasing both CoCrMo-alloy particle size and surface irregularity induces increased macrophage inflammasome activation in vitro potentially through lysosomal destabilization mechanisms. J Orthop Res. 2013 Oct; 31(10):1633-42.
Score: 0.006
-
Cobalt-alloy implant debris induce HIF-1a hypoxia associated responses: a mechanism for metal-specific orthopedic implant failure. PLoS One. 2013; 8(6):e67127.
Score: 0.006
-
CoCrMo metal-on-metal hip replacements. Phys Chem Chem Phys. 2013 Jan 21; 15(3):746-56.
Score: 0.006
-
Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem. J Bone Joint Surg Am. 2012 Oct 17; 94(20):1877-85.
Score: 0.006
-
Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res. 2012 Jul; 470(7):1814-25.
Score: 0.006
-
Evidence-based understanding of management perils for metal-on-metal hip arthroplasty patients. J Arthroplasty. 2012 Sep; 27(8 Suppl):20-5.
Score: 0.006
-
Preventing venous thromboembolic disease in patients undergoing elective total hip and knee arthroplasty. J Bone Joint Surg Am. 2012 Apr 18; 94(8):673-4.
Score: 0.006
-
A multinational assessment of metal-on-metal bearings in hip replacement. J Bone Joint Surg Am. 2011 Dec 21; 93 Suppl 3:43-7.
Score: 0.006
-
Preventing venous thromboembolic disease in patients undergoing elective hip and knee arthroplasty. J Am Acad Orthop Surg. 2011 Dec; 19(12):768-76.
Score: 0.006
-
In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
Score: 0.005
-
Early failure of metal-on-metal artificial disc prostheses associated with lymphocytic reaction: diagnosis and treatment experience in four cases. Spine (Phila Pa 1976). 2011 Apr 01; 36(7):E492-7.
Score: 0.005
-
Hematologic genetic testing in high-risk patients before knee arthroplasty: a pilot study. Clin Orthop Relat Res. 2011 Jan; 469(1):131-7.
Score: 0.005
-
Synovial fluid biomarkers for periprosthetic infection. Clin Orthop Relat Res. 2010 Aug; 468(8):2017-23.
Score: 0.005
-
Soluble ions more than particulate cobalt-alloy implant debris induce monocyte costimulatory molecule expression and release of proinflammatory cytokines critical to metal-induced lymphocyte reactivity. J Biomed Mater Res A. 2010 Jun 15; 93(4):1312-21.
Score: 0.005
-
Cruciate-retaining TKA using a third-generation system with a four-pegged tibial component: a minimum 10-year followup note. Clin Orthop Relat Res. 2010 Aug; 468(8):2160-7.
Score: 0.005
-
The evidence-based approach in bringing new orthopaedic devices to market. J Bone Joint Surg Am. 2010 Apr; 92(4):1030-7.
Score: 0.005
-
Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: a novel mechanism for implant debris reactivity. J Orthop Res. 2009 Jul; 27(7):847-54.
Score: 0.005
-
Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up, at a minimum of twenty years, of previous reports. J Bone Joint Surg Am. 2009 May; 91(5):1130-5.
Score: 0.005
-
In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants. J Biomed Mater Res B Appl Biomater. 2009 Jan; 88(1):206-19.
Score: 0.005
-
AOA symposium. Evidence-based medicine, the quality initiative, and P4P: performance or paperwork? J Bone Joint Surg Am. 2008 Dec; 90(12):2781-90.
Score: 0.005
-
Analysis of metal ion-induced DNA damage, apoptosis, and necrosis in human (Jurkat) T-cells demonstrates Ni2+ and V3+ are more toxic than other metals: Al3+, Be2+, Co2+, Cr3+, Cu2+, Fe3+, Mo5+, Nb5+, Zr2+. J Biomed Mater Res A. 2008 Sep 15; 86(4):905-13.
Score: 0.004
-
Cytokine-controlled RANKL and osteoprotegerin expression by human and mouse synovial fibroblasts: fibroblast-mediated pathologic bone resorption. Arthritis Rheum. 2008 Aug; 58(8):2397-408.
Score: 0.004
-
Modes of wear after semiconstrained total elbow arthroplasty. J Bone Joint Surg Am. 2008 Mar; 90(3):609-19.
Score: 0.004
-
Ion production and excretion in a patient with a metal-on-metal bearing hip prosthesis. A case report. J Bone Joint Surg Am. 2007 Dec; 89(12):2758-63.
Score: 0.004
-
Role of fibroblasts and fibroblast-derived growth factors in periprosthetic angiogenesis. J Orthop Res. 2007 Oct; 25(10):1378-88.
Score: 0.004
-
Preoperative testing for sepsis before revision total knee arthroplasty. J Arthroplasty. 2007 Sep; 22(6 Suppl 2):90-3.
Score: 0.004
-
Porous tantalum in reconstructive surgery of the knee: a review. J Knee Surg. 2007 Jul; 20(3):185-94.
Score: 0.004
-
The progression of patellofemoral arthrosis after medial unicompartmental replacement: results at 11 to 15 years. Clin Orthop Relat Res. 2006 Nov; 452:285-6.
Score: 0.004
-
The role of fibroblasts and fibroblast-derived factors in periprosthetic osteolysis. Arthritis Rheum. 2006 Oct; 54(10):3221-32.
Score: 0.004
-
A case of disassociation of a modular femoral neck trunion after total hip arthroplasty. J Arthroplasty. 2006 Sep; 21(6):918-21.
Score: 0.004
-
Clinical performance of contemporary tibial polyethylene components. J Arthroplasty. 2006 Aug; 21(5):754-61.
Score: 0.004
-
Chemokine gene activation in human bone marrow-derived osteoblasts following exposure to particulate wear debris. J Biomed Mater Res A. 2006 Apr; 77(1):192-201.
Score: 0.004
-
A technique for minimally invasive, quadriceps-sparing total knee arthroplasty. J Knee Surg. 2006 Jan; 19(1):63-70.
Score: 0.004
-
Outpatient total knee arthroplasty with a minimally invasive technique. J Arthroplasty. 2005 Oct; 20(7 Suppl 3):33-8.
Score: 0.004
-
The acetabular insert-metal backing interface: an additional source of polyethylene wear debris. J Arthroplasty. 2005 Oct; 20(7):914-22.
Score: 0.004
-
Extensor mechanism allograft reconstruction after total knee arthroplasty. J Bone Joint Surg Am. 2005 Sep; 87 Suppl 1(Pt 2):175-94.
Score: 0.004
-
Revision of the acetabular component without cement after total hip arthroplasty. A concise follow-up, at fifteen to nineteen years, of a previous report. J Bone Joint Surg Am. 2005 Aug; 87(8):1795-800.
Score: 0.004
-
Chemokine IL-8 induction by particulate wear debris in osteoblasts is mediated by NF-kappaB. J Orthop Res. 2005 Nov; 23(6):1249-57.
Score: 0.004
-
Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up. J Bone Joint Surg Am. 2005 May; 87(5):999-1006.
Score: 0.004
-
The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am. 2005 Apr; 87(4):781-7.
Score: 0.003
-
Rapid rehabilitation and recovery with minimally invasive total hip arthroplasty. Clin Orthop Relat Res. 2004 Dec; (429):239-47.
Score: 0.003
-
Extensor mechanism allograft reconstruction after total knee arthroplasty. A comparison of two techniques. J Bone Joint Surg Am. 2004 Dec; 86(12):2694-9.
Score: 0.003
-
The progression of patellofemoral arthrosis after medial unicompartmental replacement: results at 11 to 15 years. Clin Orthop Relat Res. 2004 Nov; (428):92-9.
Score: 0.003
-
Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up of a previous report. J Bone Joint Surg Am. 2004 Jun; 86(6):1217-22.
Score: 0.003
-
Mechanisms of failure of total hip replacements: lessons learned from retrieval studies. Clin Orthop Relat Res. 2004 Mar; (420):10-7.
Score: 0.003
-
Extended trochanteric osteotomy in complex primary total hip arthroplasty. A brief note. J Bone Joint Surg Am. 2003 Dec; 85(12):2385-90.
Score: 0.003
-
The patella in revision total knee arthroplasty. J Bone Joint Surg Am. 2003; 85-A Suppl 1:S63-70.
Score: 0.003
-
Coventry Award paper. Backsurface wear and deformation in polyethylene tibial inserts retrieved postmortem. Clin Orthop Relat Res. 2002 Nov; (404):14-23.
Score: 0.003
-
Surface damage in machined ram-extruded and net-shape molded retrieved polyethylene tibial inserts of total knee replacements. J Bone Joint Surg Am. 2002 Sep; 84(9):1534-40.
Score: 0.003
-
A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res. 2002 Aug; (401):149-61.
Score: 0.003
-
Implant design affects markers of bone resorption and formation in total hip replacement. J Bone Miner Res. 2002 May; 17(5):800-7.
Score: 0.003
-
Titanium particles induce the immediate early stress responsive chemokines IL-8 and MCP-1 in osteoblasts. J Orthop Res. 2002 May; 20(3):490-8.
Score: 0.003
-
Shedding of the interleukin-6 (IL-6) receptor (gp80) determines the ability of IL-6 to induce gp130 phosphorylation in human osteoblasts. J Biol Chem. 2002 May 10; 277(19):16879-87.
Score: 0.003