Nanoscale surface modification by anodic oxidation increased bone ingrowth and reduced fibrous tissue in the porous coating of titanium-alloy femoral hip arthroplasty implants. J Biomed Mater Res B Appl Biomater. 2017 02; 105(2):283-290.
Score: 0.126
-
Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res. 2010 Apr; 28(4):436-43.
Score: 0.086
-
How has the biologic reaction to wear particles changed with newer bearing surfaces? J Am Acad Orthop Surg. 2008; 16 Suppl 1:S49-55.
Score: 0.073
-
Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
Score: 0.073
-
Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements. J Orthop Res. 2004 Mar; 22(2):250-9.
Score: 0.056
-
Interfacial kinetics of titanium- and cobalt-based implant alloys in human serum: metal release and biofilm formation. J Biomed Mater Res A. 2003 Jun 01; 65(3):311-8.
Score: 0.053
-
Are Damage Modes Related to Microstructure and Material Loss in Severely Damaged CoCrMo Femoral Heads? Clin Orthop Relat Res. 2021 09 01; 479(9):2083-2096.
Score: 0.047
-
Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater. 2021 06; 118:104443.
Score: 0.046
-
Modelling changes in modular taper micromechanics due to surgeon assembly technique in total hip arthroplasty. Bone Joint J. 2020 Jul; 102-B(7_Supple_B):33-40.
Score: 0.044
-
In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH. Med Eng Phys. 2018 02; 52:1-9.
Score: 0.037
-
Alloy Microstructure Dictates Corrosion Modes in THA Modular Junctions. Clin Orthop Relat Res. 2017 Dec; 475(12):3026-3043.
Score: 0.036
-
Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements. J Biomed Mater Res B Appl Biomater. 2018 07; 106(5):1672-1685.
Score: 0.036
-
Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions? Clin Orthop Relat Res. 2016 Oct; 474(10):2232-42.
Score: 0.034
-
Fretting-corrosion behavior in hip implant modular junctions: The influence of friction energy and pH variation. J Mech Behav Biomed Mater. 2016 09; 62:570-587.
Score: 0.033
-
Intergranular pitting corrosion of CoCrMo biomedical implant alloy. J Biomed Mater Res B Appl Biomater. 2014 May; 102(4):850-9.
Score: 0.028
-
Increasing both CoCrMo-alloy particle size and surface irregularity induces increased macrophage inflammasome activation in vitro potentially through lysosomal destabilization mechanisms. J Orthop Res. 2013 Oct; 31(10):1633-42.
Score: 0.027
-
Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res. 2012 Jul; 470(7):1814-25.
Score: 0.025
-
In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
Score: 0.023
-
In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants. J Biomed Mater Res B Appl Biomater. 2009 Jan; 88(1):206-19.
Score: 0.020
-
A case of disassociation of a modular femoral neck trunion after total hip arthroplasty. J Arthroplasty. 2006 Sep; 21(6):918-21.
Score: 0.017
-
Clinical performance of contemporary tibial polyethylene components. J Arthroplasty. 2006 Aug; 21(5):754-61.
Score: 0.017