Joshua Jacobs to Prosthesis Failure
This is a "connection" page, showing publications Joshua Jacobs has written about Prosthesis Failure.
Connection Strength
9.267
-
Can a gait-dependent model predict wear on retrieved total knee arthroplasty components? Bone Joint J. 2020 Jun; 102-B(6_Supple_A):129-137.
Score: 0.545
-
What Factors Drive Taper Corrosion? J Arthroplasty. 2018 09; 33(9):2707-2711.
Score: 0.469
-
Diagnosing Taper Corrosion: When Is It the Taper and When Is It Something Else? J Arthroplasty. 2018 09; 33(9):2712-2715.
Score: 0.467
-
Serum Metal Levels for Diagnosis of Adverse Local Tissue Reactions?Secondary to Corrosion in Metal-on-Polyethylene Total?Hip?Arthroplasty. J Arthroplasty. 2017 09; 32(9S):S272-S277.
Score: 0.439
-
Corrosion at the Head-Neck Junction: Why Is This Happening Now? J Arthroplasty. 2016 07; 31(7):1378-80.
Score: 0.408
-
Do retrieval analysis and blood metal measurements contribute to our understanding of adverse local tissue reactions? Clin Orthop Relat Res. 2014 Dec; 472(12):3718-27.
Score: 0.373
-
Metal ion levels in maternal and placental blood after metal-on-metal total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2014 Dec; 43(12):E304-8.
Score: 0.373
-
Risk stratification algorithm for management of patients with dual modular taper total hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons and the Hip Society. J Arthroplasty. 2014 Nov; 29(11):2060-4.
Score: 0.364
-
Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am. 2013 May 15; 95(10):865-72.
Score: 0.335
-
An important contribution to our understanding of the performance of the current generation of metal-on-metal hip replacements. J Bone Joint Surg Am. 2013 Apr 17; 95(8):e53.
Score: 0.333
-
Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am. 2012 Sep 19; 94(18):1655-61.
Score: 0.320
-
In vivo oxide-induced stress corrosion cracking of Ti-6Al-4V in a neck-stem modular taper: Emergent behavior in a new mechanism of in vivo corrosion. J Biomed Mater Res B Appl Biomater. 2012 Feb; 100(2):584-94.
Score: 0.302
-
Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am. 2010 Jun; 92(6):1518-21.
Score: 0.273
-
Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res. 2010 Apr; 28(4):436-43.
Score: 0.270
-
Biologic activity of wear particles. Instr Course Lect. 2010; 59:3-16.
Score: 0.265
-
Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
Score: 0.229
-
Loosening and osteolysis associated with metal-on-metal bearings: A local effect of metal hypersensitivity? J Bone Joint Surg Am. 2006 Jun; 88(6):1171-2.
Score: 0.207
-
Wear particles. J Bone Joint Surg Am. 2006 Apr; 88 Suppl 2:99-102.
Score: 0.204
-
Are Damage Modes Related to Microstructure and Material Loss in Severely Damaged CoCrMo Femoral Heads? Clin Orthop Relat Res. 2021 09 01; 479(9):2083-2096.
Score: 0.149
-
Adverse Local Tissue Reaction due to Mechanically Assisted Crevice Corrosion Presenting as Late Instability Following Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty. 2020 09; 35(9):2666-2670.
Score: 0.135
-
What Surgeons Need to Know About Adverse Local Tissue Reaction in Total Hip Arthroplasty. J Arthroplasty. 2020 06; 35(6S):S55-S59.
Score: 0.133
-
High Failure at a Minimum 5-Year Follow-Up in Primary Total Hip Arthroplasty Using a Modular Femoral Trunnion. J Arthroplasty. 2019 07; 34(7):1395-1399.
Score: 0.125
-
Metal wear particles in hematopoietic marrow of the axial skeleton in patients with prior revision for mechanical failure of a hip or knee arthroplasty. J Biomed Mater Res B Appl Biomater. 2019 08; 107(6):1930-1936.
Score: 0.123
-
Adverse Local Tissue Reaction After a Metal-on-Metal Total Hip Prosthesis Without Elevated Serum Metal Ion Levels. Orthopedics. 2018 May 01; 41(3):e438-e441.
Score: 0.115
-
Alloy Microstructure Dictates Corrosion Modes in THA Modular Junctions. Clin Orthop Relat Res. 2017 Dec; 475(12):3026-3043.
Score: 0.113
-
Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements. J Biomed Mater Res B Appl Biomater. 2018 07; 106(5):1672-1685.
Score: 0.113
-
Aseptic Lymphocytic-Dominated Vasculitis-Associated Lesions Scores Do Not Correlate With Metal Ion Levels or Unreadable Synovial Fluid White Blood Cell Counts. J Arthroplasty. 2017 04; 32(4):1340-1343.
Score: 0.107
-
Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions? Clin Orthop Relat Res. 2016 Oct; 474(10):2232-42.
Score: 0.106
-
Fretting-corrosion behavior in hip implant modular junctions: The influence of friction energy and pH variation. J Mech Behav Biomed Mater. 2016 09; 62:570-587.
Score: 0.103
-
Do Complication Rates Differ by Gender After Metal-on-metal Hip Resurfacing Arthroplasty? A Systematic Review. Clin Orthop Relat Res. 2015 Aug; 473(8):2521-9.
Score: 0.098
-
Modern trunnions are more flexible: a mechanical analysis of THA taper designs. Clin Orthop Relat Res. 2014 Dec; 472(12):3963-70.
Score: 0.092
-
The pathology of orthopedic implant failure is mediated by innate immune system cytokines. Mediators Inflamm. 2014; 2014:185150.
Score: 0.090
-
Midterm results of a femoral stem with a modular neck design: clinical outcomes and metal ion analysis. J Arthroplasty. 2014 Sep; 29(9):1768-73.
Score: 0.089
-
Risk stratification algorithm for management of patients with metal-on-metal hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and the Hip Society. J Bone Joint Surg Am. 2014 Jan 01; 96(1):e4.
Score: 0.087
-
Cobalt-alloy implant debris induce HIF-1a hypoxia associated responses: a mechanism for metal-specific orthopedic implant failure. PLoS One. 2013; 8(6):e67127.
Score: 0.084
-
Wear-corrosion synergism in a CoCrMo hip bearing alloy is influenced by proteins. Clin Orthop Relat Res. 2012 Nov; 470(11):3109-17.
Score: 0.081
-
Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res. 2012 Jul; 470(7):1814-25.
Score: 0.079
-
In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
Score: 0.072
-
Early failure of metal-on-metal artificial disc prostheses associated with lymphocytic reaction: diagnosis and treatment experience in four cases. Spine (Phila Pa 1976). 2011 Apr 01; 36(7):E492-7.
Score: 0.072
-
In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants. J Biomed Mater Res B Appl Biomater. 2009 Jan; 88(1):206-19.
Score: 0.062
-
Biologic effects of implant debris. Bull NYU Hosp Jt Dis. 2009; 67(2):182-8.
Score: 0.062
-
How has the biologic reaction to wear particles changed with newer bearing surfaces? J Am Acad Orthop Surg. 2008; 16 Suppl 1:S49-55.
Score: 0.058
-
Rapid rehabilitation and recovery with minimally invasive total hip arthroplasty. Clin Orthop Relat Res. 2004 Dec; (429):239-47.
Score: 0.047
-
Can metal levels be used to monitor metal-on-metal hip arthroplasties? J Arthroplasty. 2004 Dec; 19(8 Suppl 3):59-65.
Score: 0.047
-
Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty. J Arthroplasty. 2004 Dec; 19(8 Suppl 3):94-101.
Score: 0.047
-
Mechanisms of failure of total hip replacements: lessons learned from retrieval studies. Clin Orthop Relat Res. 2004 Mar; (420):10-7.
Score: 0.044
-
Has Wrought Cobalt-Chromium-Molybdenum Alloy Changed for the Worse Over Time? J Arthroplasty. 2023 07; 38(7S):S280-S284.
Score: 0.042
-
Coventry Award paper. Backsurface wear and deformation in polyethylene tibial inserts retrieved postmortem. Clin Orthop Relat Res. 2002 Nov; (404):14-23.
Score: 0.040
-
A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res. 2002 Aug; (401):149-61.
Score: 0.040
-
Non-ischaemic cardiomyopathy associated with elevated serum cobalt and accelerated wear of a metal-on-metal hip resurfacing. BMJ Case Rep. 2022 Jun 27; 15(6).
Score: 0.039
-
A question of prevalence: liner dislodgment in Harris-Galante acetabular components. J Bone Joint Surg Am. 2002 Jan; 84(1):143-4.
Score: 0.038
-
Early outcomes of a modern cemented total knee arthroplasty : is tibial loosening a concern? Bone Joint J. 2021 Jun; 103-B(6 Supple A):51-58.
Score: 0.037
-
Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater. 2021 06; 118:104443.
Score: 0.036
-
Transition from metal-DTH resistance to susceptibility is facilitated by NLRP3 inflammasome signaling induced Th17 reactivity: Implications for orthopedic implants. PLoS One. 2019; 14(1):e0210336.
Score: 0.031
-
In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH. Med Eng Phys. 2018 02; 52:1-9.
Score: 0.029
-
Diagnosis and Management of Adverse Local Tissue Reactions Secondary to Corrosion at the Head-Neck Junction in Patients With Metal on Polyethylene Bearings. J Arthroplasty. 2016 Jan; 31(1):264-8.
Score: 0.024
-
Do serologic and synovial tests help diagnose infection in revision hip arthroplasty with metal-on-metal bearings or corrosion? Clin Orthop Relat Res. 2015 Feb; 473(2):498-505.
Score: 0.024
-
Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem. J Bone Joint Surg Am. 2012 Oct 17; 94(20):1877-85.
Score: 0.020
-
Synovial fluid biomarkers for periprosthetic infection. Clin Orthop Relat Res. 2010 Aug; 468(8):2017-23.
Score: 0.017
-
Cruciate-retaining TKA using a third-generation system with a four-pegged tibial component: a minimum 10-year followup note. Clin Orthop Relat Res. 2010 Aug; 468(8):2160-7.
Score: 0.017
-
Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: a novel mechanism for implant debris reactivity. J Orthop Res. 2009 Jul; 27(7):847-54.
Score: 0.016
-
Modes of wear after semiconstrained total elbow arthroplasty. J Bone Joint Surg Am. 2008 Mar; 90(3):609-19.
Score: 0.015
-
A case of disassociation of a modular femoral neck trunion after total hip arthroplasty. J Arthroplasty. 2006 Sep; 21(6):918-21.
Score: 0.013
-
Clinical performance of contemporary tibial polyethylene components. J Arthroplasty. 2006 Aug; 21(5):754-61.
Score: 0.013
-
Chemokine gene activation in human bone marrow-derived osteoblasts following exposure to particulate wear debris. J Biomed Mater Res A. 2006 Apr; 77(1):192-201.
Score: 0.013
-
The acetabular insert-metal backing interface: an additional source of polyethylene wear debris. J Arthroplasty. 2005 Oct; 20(7):914-22.
Score: 0.012
-
Revision of the acetabular component without cement after total hip arthroplasty. A concise follow-up, at fifteen to nineteen years, of a previous report. J Bone Joint Surg Am. 2005 Aug; 87(8):1795-800.
Score: 0.012
-
The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am. 2005 Apr; 87(4):781-7.
Score: 0.012
-
The progression of patellofemoral arthrosis after medial unicompartmental replacement: results at 11 to 15 years. Clin Orthop Relat Res. 2004 Nov; (428):92-9.
Score: 0.012
-
Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up of a previous report. J Bone Joint Surg Am. 2004 Jun; 86(6):1217-22.
Score: 0.011