Joshua Jacobs to Middle Aged
This is a "connection" page, showing publications Joshua Jacobs has written about Middle Aged.
Connection Strength
1.118
-
Can a gait-dependent model predict wear on retrieved total knee arthroplasty components? Bone Joint J. 2020 Jun; 102-B(6_Supple_A):129-137.
Score: 0.071
-
Adverse Local Tissue Reaction due to Mechanically Assisted Crevice Corrosion Presenting as Late Instability Following Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty. 2020 09; 35(9):2666-2670.
Score: 0.070
-
Serum Metal Levels for Diagnosis of Adverse Local Tissue Reactions?Secondary to Corrosion in Metal-on-Polyethylene Total?Hip?Arthroplasty. J Arthroplasty. 2017 09; 32(9S):S272-S277.
Score: 0.057
-
Serum Metal Concentrations in Patients With Titanium Ceramic Composite Cervical Disc Replacements. Spine (Phila Pa 1976). 2017 Mar 15; 42(6):366-371.
Score: 0.057
-
Effect of a second joint arthroplasty on metal ion levels after primary total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2013 Oct; 42(10):E84-7.
Score: 0.045
-
Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am. 2013 May 15; 95(10):865-72.
Score: 0.043
-
Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*. J Bone Joint Surg Am. 2013 Mar 20; 95(6):512-8.
Score: 0.043
-
Do ion concentrations after metal-on-metal hip resurfacing increase over time? A prospective study. J Arthroplasty. 2013 Apr; 28(4):695-700.
Score: 0.042
-
Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am. 2012 Sep 19; 94(18):1655-61.
Score: 0.041
-
Asymptomatic prospective and retrospective cohorts with metal-on-metal hip arthroplasty indicate acquired lymphocyte reactivity varies with metal ion levels on a group basis. J Orthop Res. 2013 Feb; 31(2):173-82.
Score: 0.041
-
In vivo oxide-induced stress corrosion cracking of Ti-6Al-4V in a neck-stem modular taper: Emergent behavior in a new mechanism of in vivo corrosion. J Biomed Mater Res B Appl Biomater. 2012 Feb; 100(2):584-94.
Score: 0.039
-
Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am. 2010 Jun; 92(6):1518-21.
Score: 0.035
-
Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res. 2010 Apr; 28(4):436-43.
Score: 0.035
-
Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
Score: 0.030
-
Serum metal levels and bearing surfaces in total hip arthroplasty. J Arthroplasty. 2006 Sep; 21(6 Suppl 2):47-52.
Score: 0.027
-
Lymphocyte responses in patients with total hip arthroplasty. J Orthop Res. 2005 Mar; 23(2):384-91.
Score: 0.025
-
Immune responses correlate with serum-metal in metal-on-metal hip arthroplasty. J Arthroplasty. 2004 Dec; 19(8 Suppl 3):88-93.
Score: 0.024
-
Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty. J Arthroplasty. 2004 Dec; 19(8 Suppl 3):94-101.
Score: 0.024
-
Are Damage Modes Related to Microstructure and Material Loss in Severely Damaged CoCrMo Femoral Heads? Clin Orthop Relat Res. 2021 09 01; 479(9):2083-2096.
Score: 0.019
-
COVID-19 (SARS-CoV-2) lymphocyte responses are associated with inflammatory biomarkers in total joint replacement surgery candidates pre-operatively. J Orthop Surg Res. 2021 Jun 30; 16(1):415.
Score: 0.019
-
Early outcomes of a modern cemented total knee arthroplasty : is tibial loosening a concern? Bone Joint J. 2021 Jun; 103-B(6 Supple A):51-58.
Score: 0.019
-
Joint line elevation and tibial slope are associated with increased polyethylene wear in cruciate-retaining total knee replacement. J Orthop Res. 2020 07; 38(7):1596-1606.
Score: 0.018
-
Discovery of biomarkers to identify peri-implant osteolysis before radiographic diagnosis. J Orthop Res. 2018 10; 36(10):2754-2761.
Score: 0.015
-
Females with Unexplained Joint Pain Following Total Joint Arthroplasty Exhibit a Higher Rate and Severity of Hypersensitivity to Implant Metals Compared with Males: Implications of Sex-Based Bioreactivity Differences. J Bone Joint Surg Am. 2017 Apr 19; 99(8):621-628.
Score: 0.014
-
Aseptic Lymphocytic-Dominated Vasculitis-Associated Lesions Scores Do Not Correlate With Metal Ion Levels or Unreadable Synovial Fluid White Blood Cell Counts. J Arthroplasty. 2017 04; 32(4):1340-1343.
Score: 0.014
-
Repair of Intraoperative Injury to the Medial Collateral Ligament During Primary Total Knee Arthroplasty. J Bone Joint Surg Am. 2016 Jan 06; 98(1):35-9.
Score: 0.013
-
Diagnosis and Management of Adverse Local Tissue Reactions Secondary to Corrosion at the Head-Neck Junction in Patients With Metal on Polyethylene Bearings. J Arthroplasty. 2016 Jan; 31(1):264-8.
Score: 0.013
-
Do serologic and synovial tests help diagnose infection in revision hip arthroplasty with metal-on-metal bearings or corrosion? Clin Orthop Relat Res. 2015 Feb; 473(2):498-505.
Score: 0.012
-
Midterm results of a femoral stem with a modular neck design: clinical outcomes and metal ion analysis. J Arthroplasty. 2014 Sep; 29(9):1768-73.
Score: 0.012
-
Implant debris particle size affects serum protein adsorption which may contribute to particle size-based bioreactivity differences. J Long Term Eff Med Implants. 2014; 24(1):77-88.
Score: 0.011
-
Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem. J Bone Joint Surg Am. 2012 Oct 17; 94(20):1877-85.
Score: 0.010
-
Surface damage versus tibial polyethylene insert conformity: a retrieval study. Clin Orthop Relat Res. 2012 Jul; 470(7):1814-25.
Score: 0.010
-
A multinational assessment of metal-on-metal bearings in hip replacement. J Bone Joint Surg Am. 2011 Dec 21; 93 Suppl 3:43-7.
Score: 0.010
-
In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
Score: 0.009
-
Early failure of metal-on-metal artificial disc prostheses associated with lymphocytic reaction: diagnosis and treatment experience in four cases. Spine (Phila Pa 1976). 2011 Apr 01; 36(7):E492-7.
Score: 0.009
-
Hematologic genetic testing in high-risk patients before knee arthroplasty: a pilot study. Clin Orthop Relat Res. 2011 Jan; 469(1):131-7.
Score: 0.009
-
Synovial fluid biomarkers for periprosthetic infection. Clin Orthop Relat Res. 2010 Aug; 468(8):2017-23.
Score: 0.009
-
Cruciate-retaining TKA using a third-generation system with a four-pegged tibial component: a minimum 10-year followup note. Clin Orthop Relat Res. 2010 Aug; 468(8):2160-7.
Score: 0.009
-
Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up, at a minimum of twenty years, of previous reports. J Bone Joint Surg Am. 2009 May; 91(5):1130-5.
Score: 0.008
-
Modes of wear after semiconstrained total elbow arthroplasty. J Bone Joint Surg Am. 2008 Mar; 90(3):609-19.
Score: 0.008
-
Ion production and excretion in a patient with a metal-on-metal bearing hip prosthesis. A case report. J Bone Joint Surg Am. 2007 Dec; 89(12):2758-63.
Score: 0.007
-
Role of fibroblasts and fibroblast-derived growth factors in periprosthetic angiogenesis. J Orthop Res. 2007 Oct; 25(10):1378-88.
Score: 0.007
-
Preoperative testing for sepsis before revision total knee arthroplasty. J Arthroplasty. 2007 Sep; 22(6 Suppl 2):90-3.
Score: 0.007
-
The role of fibroblasts and fibroblast-derived factors in periprosthetic osteolysis. Arthritis Rheum. 2006 Oct; 54(10):3221-32.
Score: 0.007
-
Outpatient total knee arthroplasty with a minimally invasive technique. J Arthroplasty. 2005 Oct; 20(7 Suppl 3):33-8.
Score: 0.006
-
Revision of the acetabular component without cement after total hip arthroplasty. A concise follow-up, at fifteen to nineteen years, of a previous report. J Bone Joint Surg Am. 2005 Aug; 87(8):1795-800.
Score: 0.006
-
Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up. J Bone Joint Surg Am. 2005 May; 87(5):999-1006.
Score: 0.006
-
The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am. 2005 Apr; 87(4):781-7.
Score: 0.006
-
Rapid rehabilitation and recovery with minimally invasive total hip arthroplasty. Clin Orthop Relat Res. 2004 Dec; (429):239-47.
Score: 0.006
-
Extensor mechanism allograft reconstruction after total knee arthroplasty. A comparison of two techniques. J Bone Joint Surg Am. 2004 Dec; 86(12):2694-9.
Score: 0.006
-
The progression of patellofemoral arthrosis after medial unicompartmental replacement: results at 11 to 15 years. Clin Orthop Relat Res. 2004 Nov; (428):92-9.
Score: 0.006
-
Extended trochanteric osteotomy in complex primary total hip arthroplasty. A brief note. J Bone Joint Surg Am. 2003 Dec; 85(12):2385-90.
Score: 0.006
-
Coventry Award paper. Backsurface wear and deformation in polyethylene tibial inserts retrieved postmortem. Clin Orthop Relat Res. 2002 Nov; (404):14-23.
Score: 0.005
-
Surface damage in machined ram-extruded and net-shape molded retrieved polyethylene tibial inserts of total knee replacements. J Bone Joint Surg Am. 2002 Sep; 84(9):1534-40.
Score: 0.005
-
A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res. 2002 Aug; (401):149-61.
Score: 0.005
-
Implant design affects markers of bone resorption and formation in total hip replacement. J Bone Miner Res. 2002 May; 17(5):800-7.
Score: 0.005