Joshua Jacobs to Arthroplasty, Replacement, Hip
This is a "connection" page, showing publications Joshua Jacobs has written about Arthroplasty, Replacement, Hip.
Connection Strength
11.616
-
Risk Stratification Algorithm for Management of Head-Neck Taper Tribocorrosion in Patients with Metal-on-Polyethylene Total Hip Arthroplasty: Consensus Statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and The Hip Society. J Bone Joint Surg Am. 2021 03 03; 103(5):e18.
Score: 0.425
-
Augmented Reality in Orthopedic Practice and Education. Orthop Clin North Am. 2021 Jan; 52(1):15-26.
Score: 0.420
-
Adverse Local Tissue Reaction due to Mechanically Assisted Crevice Corrosion Presenting as Late Instability Following Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty. 2020 09; 35(9):2666-2670.
Score: 0.400
-
What Surgeons Need to Know About Adverse Local Tissue Reaction in Total Hip Arthroplasty. J Arthroplasty. 2020 06; 35(6S):S55-S59.
Score: 0.393
-
Addressing Disparities in Total Hip Replacement Outcomes: Commentary on an article by Kanu Okike, MD, MPH, et al.: "Association of Race and Ethnicity with Total Hip Arthroplasty Outcomes in a Universally Insured Population". J Bone Joint Surg Am. 2019 07 03; 101(13):e66.
Score: 0.378
-
What Factors Drive Taper Corrosion? J Arthroplasty. 2018 09; 33(9):2707-2711.
Score: 0.347
-
Diagnosing Taper Corrosion: When Is It the Taper and When Is It Something Else? J Arthroplasty. 2018 09; 33(9):2712-2715.
Score: 0.345
-
Serum Metal Levels for Diagnosis of Adverse Local Tissue Reactions?Secondary to Corrosion in Metal-on-Polyethylene Total?Hip?Arthroplasty. J Arthroplasty. 2017 09; 32(9S):S272-S277.
Score: 0.325
-
Serum Metal Concentrations in Patients With Titanium Ceramic Composite Cervical Disc Replacements. Spine (Phila Pa 1976). 2017 Mar 15; 42(6):366-371.
Score: 0.323
-
Corrosion at the Head-Neck Junction: Why Is This Happening Now? J Arthroplasty. 2016 07; 31(7):1378-80.
Score: 0.301
-
Nanoscale surface modification by anodic oxidation increased bone ingrowth and reduced fibrous tissue in the porous coating of titanium-alloy femoral hip arthroplasty implants. J Biomed Mater Res B Appl Biomater. 2017 02; 105(2):283-290.
Score: 0.293
-
Reply to letter to the editor: do complication rates differ by gender after metal-on-metal hip resurfacing arthroplasty? A systematic review. Clin Orthop Relat Res. 2015 Dec; 473(12):3983-4.
Score: 0.291
-
Do Complication Rates Differ by Gender After Metal-on-metal Hip Resurfacing Arthroplasty? A Systematic Review. Clin Orthop Relat Res. 2015 Aug; 473(8):2521-9.
Score: 0.288
-
Do retrieval analysis and blood metal measurements contribute to our understanding of adverse local tissue reactions? Clin Orthop Relat Res. 2014 Dec; 472(12):3718-27.
Score: 0.275
-
Metal ion levels in maternal and placental blood after metal-on-metal total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2014 Dec; 43(12):E304-8.
Score: 0.275
-
Risk stratification algorithm for management of patients with dual modular taper total hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons and the Hip Society. J Arthroplasty. 2014 Nov; 29(11):2060-4.
Score: 0.269
-
Effect of a second joint arthroplasty on metal ion levels after primary total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2013 Oct; 42(10):E84-7.
Score: 0.254
-
Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am. 2013 May 15; 95(10):865-72.
Score: 0.247
-
An important contribution to our understanding of the performance of the current generation of metal-on-metal hip replacements. J Bone Joint Surg Am. 2013 Apr 17; 95(8):e53.
Score: 0.246
-
Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*. J Bone Joint Surg Am. 2013 Mar 20; 95(6):512-8.
Score: 0.245
-
Do ion concentrations after metal-on-metal hip resurfacing increase over time? A prospective study. J Arthroplasty. 2013 Apr; 28(4):695-700.
Score: 0.238
-
Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am. 2012 Sep 19; 94(18):1655-61.
Score: 0.236
-
Evaluation and treatment of painful total hip arthroplasties with modular metal taper junctions. Orthopedics. 2012 May; 35(5):386-91.
Score: 0.230
-
American Academy of Orthopaedic Surgeons clinical practice guideline on: preventing venous thromboembolic disease in patients undergoing elective hip and knee arthroplasty. J Bone Joint Surg Am. 2012 Apr 18; 94(8):746-7.
Score: 0.230
-
AAOS clinical practice guideline: preventing venous thromboembolic disease in patients undergoing elective hip and knee arthroplasty. J Am Acad Orthop Surg. 2011 Dec; 19(12):777-8.
Score: 0.224
-
Commentary on an article by Stephen S. Tower, MD: "Arthroprosthetic cobaltism: neurological and cardiac manifestations in two patients with metal-on-metal arthroplasty. a case report". J Bone Joint Surg Am. 2010 Dec 01; 92(17):e35.
Score: 0.209
-
Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am. 2010 Jun; 92(6):1518-21.
Score: 0.201
-
Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res. 2010 Apr; 28(4):436-43.
Score: 0.199
-
Metal-on-metal bearing surfaces. J Am Acad Orthop Surg. 2009 Feb; 17(2):69-76.
Score: 0.184
-
Analysis of retrieved acetabular components of three polyethylene types. Clin Orthop Relat Res. 2007 Dec; 465:140-9.
Score: 0.169
-
Applications of porous tantalum in total hip arthroplasty. J Am Acad Orthop Surg. 2006 Nov; 14(12):646-55.
Score: 0.157
-
Serum metal levels and bearing surfaces in total hip arthroplasty. J Arthroplasty. 2006 Sep; 21(6 Suppl 2):47-52.
Score: 0.155
-
Lymphocyte responses in patients with total hip arthroplasty. J Orthop Res. 2005 Mar; 23(2):384-91.
Score: 0.140
-
Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty. J Bone Joint Surg Am. 2003 Jun; 85(6):1111-7.
Score: 0.124
-
Has Wrought Cobalt-Chromium-Molybdenum Alloy Changed for the Worse Over Time? J Arthroplasty. 2023 07; 38(7S):S280-S284.
Score: 0.123
-
Non-ischaemic cardiomyopathy associated with elevated serum cobalt and accelerated wear of a metal-on-metal hip resurfacing. BMJ Case Rep. 2022 Jun 27; 15(6).
Score: 0.116
-
A question of prevalence: liner dislodgment in Harris-Galante acetabular components. J Bone Joint Surg Am. 2002 Jan; 84(1):143-4.
Score: 0.112
-
Are Damage Modes Related to Microstructure and Material Loss in Severely Damaged CoCrMo Femoral Heads? Clin Orthop Relat Res. 2021 09 01; 479(9):2083-2096.
Score: 0.110
-
The role of Vitamin E in hip implant-related corrosion and toxicity: Initial outcome. J Mech Behav Biomed Mater. 2021 11; 123:104769.
Score: 0.109
-
Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater. 2021 06; 118:104443.
Score: 0.106
-
Modelling changes in modular taper micromechanics due to surgeon assembly technique in total hip arthroplasty. Bone Joint J. 2020 Jul; 102-B(7_Supple_B):33-40.
Score: 0.101
-
Echocardiographic Changes in the Context of Metal-on-Metal Versus Nonmetal-on-Metal Total Hip Arthroplasty. J Arthroplasty. 2020 11; 35(11):3230-3236.e3.
Score: 0.101
-
High Failure at a Minimum 5-Year Follow-Up in Primary Total Hip Arthroplasty Using a Modular Femoral Trunnion. J Arthroplasty. 2019 07; 34(7):1395-1399.
Score: 0.093
-
Metal wear particles in hematopoietic marrow of the axial skeleton in patients with prior revision for mechanical failure of a hip or knee arthroplasty. J Biomed Mater Res B Appl Biomater. 2019 08; 107(6):1930-1936.
Score: 0.091
-
Discovery of biomarkers to identify peri-implant osteolysis before radiographic diagnosis. J Orthop Res. 2018 10; 36(10):2754-2761.
Score: 0.088
-
Risk Adjustment Is Necessary in Medicare Bundled Payment Models for Total Hip and Knee Arthroplasty. J Arthroplasty. 2018 08; 33(8):2368-2375.
Score: 0.086
-
Alloy Microstructure Dictates Corrosion Modes in THA Modular Junctions. Clin Orthop Relat Res. 2017 Dec; 475(12):3026-3043.
Score: 0.083
-
Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements. J Biomed Mater Res B Appl Biomater. 2018 07; 106(5):1672-1685.
Score: 0.083
-
Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions? Clin Orthop Relat Res. 2016 Oct; 474(10):2232-42.
Score: 0.078
-
Modern trunnions are more flexible: a mechanical analysis of THA taper designs. Clin Orthop Relat Res. 2014 Dec; 472(12):3963-70.
Score: 0.068
-
Midterm results of a femoral stem with a modular neck design: clinical outcomes and metal ion analysis. J Arthroplasty. 2014 Sep; 29(9):1768-73.
Score: 0.066
-
Risk stratification algorithm for management of patients with metal-on-metal hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and the Hip Society. J Bone Joint Surg Am. 2014 Jan 01; 96(1):e4.
Score: 0.065
-
CoCrMo metal-on-metal hip replacements. Phys Chem Chem Phys. 2013 Jan 21; 15(3):746-56.
Score: 0.060
-
Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem. J Bone Joint Surg Am. 2012 Oct 17; 94(20):1877-85.
Score: 0.059
-
Asymptomatic prospective and retrospective cohorts with metal-on-metal hip arthroplasty indicate acquired lymphocyte reactivity varies with metal ion levels on a group basis. J Orthop Res. 2013 Feb; 31(2):173-82.
Score: 0.059
-
Preventing venous thromboembolic disease in patients undergoing elective total hip and knee arthroplasty. J Bone Joint Surg Am. 2012 Apr 18; 94(8):673-4.
Score: 0.057
-
Preventing venous thromboembolic disease in patients undergoing elective hip and knee arthroplasty. J Am Acad Orthop Surg. 2011 Dec; 19(12):768-76.
Score: 0.056
-
In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am. 2011 Apr 06; 93(7):e27.
Score: 0.053
-
Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up, at a minimum of twenty years, of previous reports. J Bone Joint Surg Am. 2009 May; 91(5):1130-5.
Score: 0.047
-
Ion production and excretion in a patient with a metal-on-metal bearing hip prosthesis. A case report. J Bone Joint Surg Am. 2007 Dec; 89(12):2758-63.
Score: 0.042
-
A case of disassociation of a modular femoral neck trunion after total hip arthroplasty. J Arthroplasty. 2006 Sep; 21(6):918-21.
Score: 0.039
-
Revision of the acetabular component without cement after total hip arthroplasty. A concise follow-up, at fifteen to nineteen years, of a previous report. J Bone Joint Surg Am. 2005 Aug; 87(8):1795-800.
Score: 0.036
-
Rapid rehabilitation and recovery with minimally invasive total hip arthroplasty. Clin Orthop Relat Res. 2004 Dec; (429):239-47.
Score: 0.034
-
Can metal levels be used to monitor metal-on-metal hip arthroplasties? J Arthroplasty. 2004 Dec; 19(8 Suppl 3):59-65.
Score: 0.034
-
Immune responses correlate with serum-metal in metal-on-metal hip arthroplasty. J Arthroplasty. 2004 Dec; 19(8 Suppl 3):88-93.
Score: 0.034
-
Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty. J Arthroplasty. 2004 Dec; 19(8 Suppl 3):94-101.
Score: 0.034
-
Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up of a previous report. J Bone Joint Surg Am. 2004 Jun; 86(6):1217-22.
Score: 0.033
-
Mechanisms of failure of total hip replacements: lessons learned from retrieval studies. Clin Orthop Relat Res. 2004 Mar; (420):10-7.
Score: 0.033
-
Extended trochanteric osteotomy in complex primary total hip arthroplasty. A brief note. J Bone Joint Surg Am. 2003 Dec; 85(12):2385-90.
Score: 0.032
-
A multicenter retrieval study of the taper interfaces of modular hip prostheses. Clin Orthop Relat Res. 2002 Aug; (401):149-61.
Score: 0.029
-
Fourier transform infrared spectroscopic imaging of wear and corrosion products within joint capsule tissue from total hip replacements patients. J Biomed Mater Res B Appl Biomater. 2020 02; 108(2):513-526.
Score: 0.023
-
Adverse Local Tissue Reaction After a Metal-on-Metal Total Hip Prosthesis Without Elevated Serum Metal Ion Levels. Orthopedics. 2018 May 01; 41(3):e438-e441.
Score: 0.021
-
Females with Unexplained Joint Pain Following Total Joint Arthroplasty Exhibit a Higher Rate and Severity of Hypersensitivity to Implant Metals Compared with Males: Implications of Sex-Based Bioreactivity Differences. J Bone Joint Surg Am. 2017 Apr 19; 99(8):621-628.
Score: 0.020
-
Aseptic Lymphocytic-Dominated Vasculitis-Associated Lesions Scores Do Not Correlate With Metal Ion Levels or Unreadable Synovial Fluid White Blood Cell Counts. J Arthroplasty. 2017 04; 32(4):1340-1343.
Score: 0.020
-
Diagnosis and Management of Adverse Local Tissue Reactions Secondary to Corrosion at the Head-Neck Junction in Patients With Metal on Polyethylene Bearings. J Arthroplasty. 2016 Jan; 31(1):264-8.
Score: 0.018
-
Wear-corrosion synergism in a CoCrMo hip bearing alloy is influenced by proteins. Clin Orthop Relat Res. 2012 Nov; 470(11):3109-17.
Score: 0.015
-
The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am. 2005 Apr; 87(4):781-7.
Score: 0.009