Co-Authors
This is a "connection" page, showing publications co-authored by Richard Trohman and Timothy Larsen.
Connection Strength
2.487
-
Evolving Concepts in Cardiac Physiologic Pacing in the Era of Conduction System Pacing. Am J Cardiol. 2023 Nov 26; 212:51-66.
Score: 0.230
-
Comparison of ablation index versus time-guided radiofrequency energy dosing using normal and half-normal saline irrigation in a porcine left ventricular model. J Cardiovasc Electrophysiol. 2022 04; 33(4):698-712.
Score: 0.203
-
Comparison of radiofrequency ablation from the coronary cusps and endocardial left ventricular outflow tract for left ventricular summit ventricular arrhythmias in a porcine and infrared thermal model. J Cardiovasc Electrophysiol. 2022 03; 33(3):551-556.
Score: 0.203
-
Use of infrared thermography to delineate temperature gradients and critical isotherms during catheter ablation with normal and half normal saline: Implications for safety and efficacy. J Cardiovasc Electrophysiol. 2021 08; 32(8):2035-2044.
Score: 0.194
-
Sensors for rate-adaptive pacing: How they work, strengths, and limitations. J Cardiovasc Electrophysiol. 2020 11; 31(11):3009-3027.
Score: 0.185
-
Cryoballoon Ablation and Bipolar Voltage Mapping in Patients With Left Atrial Appendage Occlusion Devices. Am J Cardiol. 2020 11 15; 135:99-104.
Score: 0.184
-
Comparison between minimal fluoroscopy and conventional approaches for visually guided laser balloon pulmonary vein isolation ablation. J Cardiovasc Electrophysiol. 2020 07; 31(7):1608-1615.
Score: 0.181
-
Supplemental Radiofrequency Ablation After Acutely Unsuccessful Cryoballoon Pulmonary Vein Isolation is Associated With Increased Risk of Recurrent Atrial Fibrillation. J Am Heart Assoc. 2020 05 18; 9(10):e015979.
Score: 0.180
-
Meta-analysis of pulmonary vein isolation ablation for atrial fibrillation conventional vs low- and zero-fluoroscopy approaches. J Cardiovasc Electrophysiol. 2020 06; 31(6):1403-1412.
Score: 0.179
-
Novel Intraprocedural Assessment of the Optimal Modality for Cardiac Resynchronization in Patients With LBBB/IVCD?Pattern. JACC Clin Electrophysiol. 2023 Dec; 9(12):2652-2654.
Score: 0.057
-
Subcutaneous implantable cardioverter-defibrillator implantation position predicts successful defibrillation in obese and non-obese patients. J Interv Card Electrophysiol. 2023 Jan 03.
Score: 0.054
-
A systematic review and meta-analysis comparing radiofrequency catheter ablation with medical therapy for ventricular tachycardia in patients with ischemic and non-ischemic cardiomyopathies. J Interv Card Electrophysiol. 2023 Jan; 66(1):161-175.
Score: 0.052
-
Comparison of electrocautery platforms for pulse generator replacement procedures. J Interv Card Electrophysiol. 2022 09; 64(3):557-558.
Score: 0.052
-
Wide area circumferential ablation for pulmonary vein isolation using radiofrequency versus laser balloon ablation. J Arrhythm. 2022 Jun; 38(3):336-345.
Score: 0.052
-
Clinical outcomes of conduction system pacing compared to biventricular pacing in patients requiring cardiac resynchronization therapy. Heart Rhythm. 2022 08; 19(8):1263-1271.
Score: 0.052
-
New-Onset Atrial Fibrillation in Left Bundle Branch Area Pacing Compared With Right Ventricular Pacing. Circ Arrhythm Electrophysiol. 2022 04; 15(4):e010710.
Score: 0.051
-
Mortality benefit of catheter ablation versus medical therapy in atrial fibrillation: An RCT only meta-analysis. J Cardiovasc Electrophysiol. 2022 02; 33(2):178-193.
Score: 0.050
-
Clinical outcomes of left bundle branch area pacing compared to right ventricular pacing: Results from the Geisinger-Rush Conduction System Pacing Registry. Heart Rhythm. 2022 01; 19(1):3-11.
Score: 0.049
-
High-power short duration vs. conventional radiofrequency ablation of atrial fibrillation: a systematic review and meta-analysis. Europace. 2021 05 21; 23(5):710-721.
Score: 0.048
-
Pros and Cons of Left Bundle Branch Pacing: A Single-Center Experience. Circ Arrhythm Electrophysiol. 2020 12; 13(12):e008874.
Score: 0.047
-
Development of New-Onset or Progressive Atrial Fibrillation in Patients With Permanent HIS Bundle Pacing Versus Right Ventricular Pacing: Results From the RUSH HBP Registry. J Am Heart Assoc. 2020 11 17; 9(22):e018478.
Score: 0.047
-
Safety and Effectiveness of Hydroxychloroquine and Azithromycin Combination Therapy for Treatment of Hospitalized Patients with COVID-19: A Propensity-Matched Study. Cardiol Ther. 2020 Dec; 9(2):523-534.
Score: 0.046
-
A systematic review and meta-analysis comparing second-generation cryoballoon and contact force radiofrequency ablation for initial ablation of paroxysmal and persistent atrial fibrillation. J Cardiovasc Electrophysiol. 2020 10; 31(10):2559-2571.
Score: 0.046
-
Late-onset interventricular septal perforation from left bundle branch pacing. HeartRhythm Case Rep. 2020 Sep; 6(9):627-631.
Score: 0.045