Robert Urban to Middle Aged
This is a "connection" page, showing publications Robert Urban has written about Middle Aged.
Connection Strength
0.174
-
Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem. J Bone Joint Surg Am. 2012 Oct 17; 94(20):1877-85.
Score: 0.040
-
Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty. J Arthroplasty. 2004 Dec; 19(8 Suppl 3):94-101.
Score: 0.023
-
Adverse Local Tissue Reaction due to Mechanically Assisted Crevice Corrosion Presenting as Late Instability Following Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty. 2020 09; 35(9):2666-2670.
Score: 0.017
-
Adverse Local Tissue Responses to Failed Temporomandibular Joint Implants. J Oral Maxillofac Surg. 2017 Oct; 75(10):2076-2084.
Score: 0.014
-
Aseptic Lymphocytic-Dominated Vasculitis-Associated Lesions Scores Do Not Correlate With Metal Ion Levels or Unreadable Synovial Fluid White Blood Cell Counts. J Arthroplasty. 2017 04; 32(4):1340-1343.
Score: 0.013
-
How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study. Clin Orthop Relat Res. 2016 Aug; 474(8):1867-75.
Score: 0.013
-
Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am. 2013 May 15; 95(10):865-72.
Score: 0.010
-
In vivo oxide-induced stress corrosion cracking of Ti-6Al-4V in a neck-stem modular taper: Emergent behavior in a new mechanism of in vivo corrosion. J Biomed Mater Res B Appl Biomater. 2012 Feb; 100(2):584-94.
Score: 0.009
-
Early failure of metal-on-metal artificial disc prostheses associated with lymphocytic reaction: diagnosis and treatment experience in four cases. Spine (Phila Pa 1976). 2011 Apr 01; 36(7):E492-7.
Score: 0.009
-
Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am. 2010 Jun; 92(6):1518-21.
Score: 0.008
-
Modes of wear after semiconstrained total elbow arthroplasty. J Bone Joint Surg Am. 2008 Mar; 90(3):609-19.
Score: 0.007
-
Implantation of the femoral stem into a bed of titanium granules using vibration: a pilot study of a new method for prosthetic fixation in 5 patients followed for up to 15 years. Ups J Med Sci. 2007; 112(2):183-9.
Score: 0.007
-
Coventry Award paper. Backsurface wear and deformation in polyethylene tibial inserts retrieved postmortem. Clin Orthop Relat Res. 2002 Nov; (404):14-23.
Score: 0.005