Header Logo

Connection

Robert Urban to Arthroplasty, Replacement, Hip

This is a "connection" page, showing publications Robert Urban has written about Arthroplasty, Replacement, Hip.
Connection Strength

2.024
  1. Metal wear particles in hematopoietic marrow of the axial skeleton in patients with prior revision for mechanical failure of a hip or knee arthroplasty. J Biomed Mater Res B Appl Biomater. 2019 08; 107(6):1930-1936.
    View in: PubMed
    Score: 0.356
  2. Alloy Microstructure Dictates Corrosion Modes in THA Modular Junctions. Clin Orthop Relat Res. 2017 Dec; 475(12):3026-3043.
    View in: PubMed
    Score: 0.326
  3. Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements. J Biomed Mater Res B Appl Biomater. 2018 07; 106(5):1672-1685.
    View in: PubMed
    Score: 0.326
  4. Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem. J Bone Joint Surg Am. 2012 Oct 17; 94(20):1877-85.
    View in: PubMed
    Score: 0.233
  5. Adverse Local Tissue Reaction due to Mechanically Assisted Crevice Corrosion Presenting as Late Instability Following Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty. 2020 09; 35(9):2666-2670.
    View in: PubMed
    Score: 0.098
  6. Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions? Clin Orthop Relat Res. 2016 Oct; 474(10):2232-42.
    View in: PubMed
    Score: 0.077
  7. How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study. Clin Orthop Relat Res. 2016 Aug; 474(8):1867-75.
    View in: PubMed
    Score: 0.073
  8. Nanoscale surface modification by anodic oxidation increased bone ingrowth and reduced fibrous tissue in the porous coating of titanium-alloy femoral hip arthroplasty implants. J Biomed Mater Res B Appl Biomater. 2017 02; 105(2):283-290.
    View in: PubMed
    Score: 0.072
  9. Modern trunnions are more flexible: a mechanical analysis of THA taper designs. Clin Orthop Relat Res. 2014 Dec; 472(12):3963-70.
    View in: PubMed
    Score: 0.067
  10. Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am. 2013 May 15; 95(10):865-72.
    View in: PubMed
    Score: 0.061
  11. Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am. 2010 Jun; 92(6):1518-21.
    View in: PubMed
    Score: 0.049
  12. Metal-on-metal bearing surfaces. J Am Acad Orthop Surg. 2009 Feb; 17(2):69-76.
    View in: PubMed
    Score: 0.045
  13. Three-dimensional laser micrometry characterization of surface wear in total hip arthroplasty. J Biomed Mater Res B Appl Biomater. 2007 Aug; 82(2):428-39.
    View in: PubMed
    Score: 0.041
  14. Effect of hip hemiarthroplasty on articular cartilage and bone in a canine model. Clin Orthop Relat Res. 2005 Aug; (437):157-63.
    View in: PubMed
    Score: 0.035
  15. Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty. J Arthroplasty. 2004 Dec; 19(8 Suppl 3):94-101.
    View in: PubMed
    Score: 0.034
  16. Mechanisms of failure of total hip replacements: lessons learned from retrieval studies. Clin Orthop Relat Res. 2004 Mar; (420):10-7.
    View in: PubMed
    Score: 0.032
  17. Autopsy analysis thirty years after metal-on-metal total hip replacement. A case report. J Bone Joint Surg Am. 2003 Nov; 85(11):2218-22.
    View in: PubMed
    Score: 0.031
  18. Fourier transform infrared spectroscopic imaging of wear and corrosion products within joint capsule tissue from total hip replacements patients. J Biomed Mater Res B Appl Biomater. 2020 02; 108(2):513-526.
    View in: PubMed
    Score: 0.023
  19. Aseptic Lymphocytic-Dominated Vasculitis-Associated Lesions Scores Do Not Correlate With Metal Ion Levels or Unreadable Synovial Fluid White Blood Cell Counts. J Arthroplasty. 2017 04; 32(4):1340-1343.
    View in: PubMed
    Score: 0.019
  20. Implantation of the femoral stem into a bed of titanium granules using vibration: a pilot study of a new method for prosthetic fixation in 5 patients followed for up to 15 years. Ups J Med Sci. 2007; 112(2):183-9.
    View in: PubMed
    Score: 0.010
  21. Bone ingrowth through porous titanium granulate around a femoral stem: histological assessment in a six-month canine hemiarthroplasty model. Ups J Med Sci. 2007; 112(2):191-7.
    View in: PubMed
    Score: 0.010
  22. Can metal levels be used to monitor metal-on-metal hip arthroplasties? J Arthroplasty. 2004 Dec; 19(8 Suppl 3):59-65.
    View in: PubMed
    Score: 0.008
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.