Robert Urban to Arthroplasty, Replacement, Hip
This is a "connection" page, showing publications Robert Urban has written about Arthroplasty, Replacement, Hip.
Connection Strength
2.024
-
Metal wear particles in hematopoietic marrow of the axial skeleton in patients with prior revision for mechanical failure of a hip or knee arthroplasty. J Biomed Mater Res B Appl Biomater. 2019 08; 107(6):1930-1936.
Score: 0.356
-
Alloy Microstructure Dictates Corrosion Modes in THA Modular Junctions. Clin Orthop Relat Res. 2017 Dec; 475(12):3026-3043.
Score: 0.326
-
Mechanical, chemical and biological damage modes within head-neck tapers of CoCrMo and Ti6Al4V contemporary hip replacements. J Biomed Mater Res B Appl Biomater. 2018 07; 106(5):1672-1685.
Score: 0.326
-
Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem. J Bone Joint Surg Am. 2012 Oct 17; 94(20):1877-85.
Score: 0.233
-
Adverse Local Tissue Reaction due to Mechanically Assisted Crevice Corrosion Presenting as Late Instability Following Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty. 2020 09; 35(9):2666-2670.
Score: 0.098
-
Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions? Clin Orthop Relat Res. 2016 Oct; 474(10):2232-42.
Score: 0.077
-
How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study. Clin Orthop Relat Res. 2016 Aug; 474(8):1867-75.
Score: 0.073
-
Nanoscale surface modification by anodic oxidation increased bone ingrowth and reduced fibrous tissue in the porous coating of titanium-alloy femoral hip arthroplasty implants. J Biomed Mater Res B Appl Biomater. 2017 02; 105(2):283-290.
Score: 0.072
-
Modern trunnions are more flexible: a mechanical analysis of THA taper designs. Clin Orthop Relat Res. 2014 Dec; 472(12):3963-70.
Score: 0.067
-
Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am. 2013 May 15; 95(10):865-72.
Score: 0.061
-
Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am. 2010 Jun; 92(6):1518-21.
Score: 0.049
-
Metal-on-metal bearing surfaces. J Am Acad Orthop Surg. 2009 Feb; 17(2):69-76.
Score: 0.045
-
Three-dimensional laser micrometry characterization of surface wear in total hip arthroplasty. J Biomed Mater Res B Appl Biomater. 2007 Aug; 82(2):428-39.
Score: 0.041
-
Effect of hip hemiarthroplasty on articular cartilage and bone in a canine model. Clin Orthop Relat Res. 2005 Aug; (437):157-63.
Score: 0.035
-
Accumulation in liver and spleen of metal particles generated at nonbearing surfaces in hip arthroplasty. J Arthroplasty. 2004 Dec; 19(8 Suppl 3):94-101.
Score: 0.034
-
Mechanisms of failure of total hip replacements: lessons learned from retrieval studies. Clin Orthop Relat Res. 2004 Mar; (420):10-7.
Score: 0.032
-
Autopsy analysis thirty years after metal-on-metal total hip replacement. A case report. J Bone Joint Surg Am. 2003 Nov; 85(11):2218-22.
Score: 0.031
-
Fourier transform infrared spectroscopic imaging of wear and corrosion products within joint capsule tissue from total hip replacements patients. J Biomed Mater Res B Appl Biomater. 2020 02; 108(2):513-526.
Score: 0.023
-
Aseptic Lymphocytic-Dominated Vasculitis-Associated Lesions Scores Do Not Correlate With Metal Ion Levels or Unreadable Synovial Fluid White Blood Cell Counts. J Arthroplasty. 2017 04; 32(4):1340-1343.
Score: 0.019
-
Implantation of the femoral stem into a bed of titanium granules using vibration: a pilot study of a new method for prosthetic fixation in 5 patients followed for up to 15 years. Ups J Med Sci. 2007; 112(2):183-9.
Score: 0.010
-
Bone ingrowth through porous titanium granulate around a femoral stem: histological assessment in a six-month canine hemiarthroplasty model. Ups J Med Sci. 2007; 112(2):191-7.
Score: 0.010
-
Can metal levels be used to monitor metal-on-metal hip arthroplasties? J Arthroplasty. 2004 Dec; 19(8 Suppl 3):59-65.
Score: 0.008