Bernard Bach to Bone Screws
This is a "connection" page, showing publications Bernard Bach has written about Bone Screws.
Connection Strength
2.082
-
Bioabsorbable versus metallic interference screws in anterior cruciate ligament reconstruction: a systematic review of overlapping meta-analyses. Arthroscopy. 2015 Mar; 31(3):561-8.
Score: 0.441
-
Screw fixation of an OCD loose body: 21-year results. J Knee Surg. 2013 Dec; 26 Suppl 1:S77-80.
Score: 0.368
-
Special report: observations on interference screw morphologies. Arthroscopy. 2000 Jul; 16(5):E10.
Score: 0.162
-
Migration of femoral interference screw after anterior cruciate ligament reconstruction. Am J Knee Surg. 1998; 11(1):32-4.
Score: 0.136
-
Interference screw divergence in endoscopic anterior cruciate ligament reconstruction. Arthroscopy. 1996 Feb; 12(1):45-9.
Score: 0.119
-
Subpectoral Biceps Tenodesis. Am J Orthop (Belle Mead NJ). 2016 Feb; 45(2):68-74.
Score: 0.119
-
The arthroscopic-assisted removal of a distal femoral condylar locking plate--a case report. Bull Hosp Jt Dis (2013). 2014; 72(2):185-8.
Score: 0.103
-
Arthroscopic removal of painful Bristow hardware. Arthroscopy. 1990; 6(4):324-6.
Score: 0.078
-
Tibial fixation of anterior cruciate ligament allograft tendons: comparison of 1-, 2-, and 4-stranded constructs. Am J Sports Med. 2009 Aug; 37(8):1531-8.
Score: 0.075
-
Biomechanical evaluation of bioabsorbable versus metallic screws for posterior cruciate ligament inlay graft fixation: a comparative study. Am J Sports Med. 2009 Apr; 37(4):748-53.
Score: 0.073
-
Internal fixation of unstable Cahill Type-2C osteochondritis dissecans lesions of the knee in adolescent patients. Orthopedics. 2007 06; 30(6):487-90.
Score: 0.065
-
Late anterior cruciate ligament reconstruction failure by femoral bone plug dislodgement. Case report. J Knee Surg. 2006 Jul; 19(3):202-5.
Score: 0.061
-
Displaced nonunion patellar fracture following use of a patellar tendon autograft for ACL reconstruction: case report. J Knee Surg. 2005 Apr; 18(2):131-4.
Score: 0.056
-
Posterior cruciate ligament reconstruction: current trends. J Knee Surg. 2004 Jul; 17(3):133-9.
Score: 0.053
-
Arthroscopic anterior cruciate ligament reconstruction using patellar tendon autografts: a comprehensive review of contemporary literature. Am J Knee Surg. 2001; 14(4):243-58.
Score: 0.042
-
Management of Isolated Greater Tuberosity Fractures: A Systematic Review. Am J Orthop (Belle Mead NJ). 2017 Nov/Dec; 46(6):E445-E453.
Score: 0.034
-
Comparison of screw post fixation and free bone block interference fixation for anterior cruciate ligament soft tissue grafts: biomechanical considerations. Arthroscopy. 1996 Aug; 12(4):470-3.
Score: 0.031
-
Comparison of "inside-out" and "outside-in" interference screw fixation for anterior cruciate ligament surgery in a bovine knee. Arthroscopy. 1996 Feb; 12(1):76-81.
Score: 0.030
-
Intraarticular placement of Kurosaka interference screws. Arthroscopy. 1994 Aug; 10(4):412-7.
Score: 0.027
-
Anterior cruciate ligament reconstruction in men and women: An outcome analysis comparing gender. Arthroscopy. 2001 Jul; 17(6):588-96.
Score: 0.011