Header Logo

Connection

Nadim Hallab to Humans

This is a "connection" page, showing publications Nadim Hallab has written about Humans.
Connection Strength

0.619
  1. COVID-19 (SARS-CoV-2) lymphocyte responses are associated with inflammatory biomarkers in total joint replacement surgery candidates pre-operatively. J Orthop Surg Res. 2021 Jun 30; 16(1):415.
    View in: PubMed
    Score: 0.057
  2. Females with Unexplained Joint Pain Following Total Joint Arthroplasty Exhibit a Higher Rate and Severity of Hypersensitivity to Implant Metals Compared with Males: Implications of Sex-Based Bioreactivity Differences. J Bone Joint Surg Am. 2017 Apr 19; 99(8):621-628.
    View in: PubMed
    Score: 0.043
  3. Cobalt Alloy Implant Debris Induces Inflammation and Bone Loss Primarily through Danger Signaling, Not TLR4 Activation: Implications for DAMP-ening Implant Related Inflammation. PLoS One. 2016; 11(7):e0160141.
    View in: PubMed
    Score: 0.041
  4. Metal sensitivities among TJA patients with post-operative pain: indications for multi-metal LTT testing. J Long Term Eff Med Implants. 2014; 24(1):37-44.
    View in: PubMed
    Score: 0.034
  5. Growth guidance system for early-onset scoliosis: comparison of experimental and retrieval wear. Spine (Phila Pa 1976). 2013 Aug 15; 38(18):1546-53.
    View in: PubMed
    Score: 0.033
  6. Asymptomatic prospective and retrospective cohorts with metal-on-metal hip arthroplasty indicate acquired lymphocyte reactivity varies with metal ion levels on a group basis. J Orthop Res. 2013 Feb; 31(2):173-82.
    View in: PubMed
    Score: 0.031
  7. Orthopedic implant cobalt-alloy particles produce greater toxicity and inflammatory cytokines than titanium alloy and zirconium alloy-based particles in vitro, in human osteoblasts, fibroblasts, and macrophages. J Biomed Mater Res A. 2012 Aug; 100(8):2147-58.
    View in: PubMed
    Score: 0.030
  8. Soluble ions more than particulate cobalt-alloy implant debris induce monocyte costimulatory molecule expression and release of proinflammatory cytokines critical to metal-induced lymphocyte reactivity. J Biomed Mater Res A. 2010 Jun 15; 93(4):1312-21.
    View in: PubMed
    Score: 0.027
  9. Soluble and particulate Co-Cr-Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: a novel mechanism for implant debris reactivity. J Orthop Res. 2009 Jul; 27(7):847-54.
    View in: PubMed
    Score: 0.025
  10. Biologic effects of implant debris. Bull NYU Hosp Jt Dis. 2009; 67(2):182-8.
    View in: PubMed
    Score: 0.024
  11. Analysis of metal ion-induced DNA damage, apoptosis, and necrosis in human (Jurkat) T-cells demonstrates Ni2+ and V3+ are more toxic than other metals: Al3+, Be2+, Co2+, Cr3+, Cu2+, Fe3+, Mo5+, Nb5+, Zr2+. J Biomed Mater Res A. 2008 Sep 15; 86(4):905-13.
    View in: PubMed
    Score: 0.024
  12. Loosening and osteolysis associated with metal-on-metal bearings: A local effect of metal hypersensitivity? J Bone Joint Surg Am. 2006 Jun; 88(6):1171-2.
    View in: PubMed
    Score: 0.020
  13. Immune responses correlate with serum-metal in metal-on-metal hip arthroplasty. J Arthroplasty. 2004 Dec; 19(8 Suppl 3):88-93.
    View in: PubMed
    Score: 0.018
  14. Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements. J Orthop Res. 2004 Mar; 22(2):250-9.
    View in: PubMed
    Score: 0.017
  15. Biomaterial optimization in total disc arthroplasty. Spine (Phila Pa 1976). 2003 Oct 15; 28(20):S139-52.
    View in: PubMed
    Score: 0.017
  16. Concentration- and composition-dependent effects of metal ions on human MG-63 osteoblasts. J Biomed Mater Res. 2002 Jun 05; 60(3):420-33.
    View in: PubMed
    Score: 0.015
  17. Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal-protein complexes produced from cobalt-base and titanium-base implant alloy degradation. Mol Cell Biochem. 2001 Jun; 222(1-2):127-36.
    View in: PubMed
    Score: 0.014
  18. Fretting-corrosion in hip taper modular junctions: The influence of topography and pH levels - An in-vitro study. J Mech Behav Biomed Mater. 2021 06; 118:104443.
    View in: PubMed
    Score: 0.014
  19. Evaluation of metallic and polymeric biomaterial surface energy and surface roughness characteristics for directed cell adhesion. Tissue Eng. 2001 Feb; 7(1):55-71.
    View in: PubMed
    Score: 0.014
  20. A triple assay technique for the evaluation of metal-induced, delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty. J Biomed Mater Res. 2000 Sep; 53(5):480-9.
    View in: PubMed
    Score: 0.014
  21. Hypersensitivity to metallic biomaterials: a review of leukocyte migration inhibition assays. Biomaterials. 2000 Jul; 21(13):1301-14.
    View in: PubMed
    Score: 0.013
  22. Sterile particle-induced inflammation is mediated by macrophages releasing IL-33 through a Bruton's tyrosine kinase-dependent pathway. Nat Mater. 2019 03; 18(3):289-297.
    View in: PubMed
    Score: 0.012
  23. Cell adhesion to biomaterials: correlations between surface charge, surface roughness, adsorbed protein, and cell morphology. J Long Term Eff Med Implants. 1995; 5(3):209-31.
    View in: PubMed
    Score: 0.009
  24. Effect of a second joint arthroplasty on metal ion levels after primary total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2013 Oct; 42(10):E84-7.
    View in: PubMed
    Score: 0.008
  25. Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*. J Bone Joint Surg Am. 2013 Mar 20; 95(6):512-8.
    View in: PubMed
    Score: 0.008
  26. Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: synergistic interactions of wear and corrosion. J Biomed Mater Res B Appl Biomater. 2012 Aug; 100(6):1662-71.
    View in: PubMed
    Score: 0.008
  27. Calcineurin/nuclear factor of activated T cells (NFAT) signaling in cobalt-chromium-molybdenum (CoCrMo) particles-induced tumor necrosis factor-a (TNFa) secretion in MLO-Y4 osteocytes. J Orthop Res. 2011 Dec; 29(12):1867-73.
    View in: PubMed
    Score: 0.007
  28. Synovial fluid biomarkers for periprosthetic infection. Clin Orthop Relat Res. 2010 Aug; 468(8):2017-23.
    View in: PubMed
    Score: 0.007
  29. Metal-on-metal bearing surfaces. J Am Acad Orthop Surg. 2009 Feb; 17(2):69-76.
    View in: PubMed
    Score: 0.006
  30. A critical evaluation of discography in patients with lumbar intervertebral disc disease. Spine J. 2008 Jul-Aug; 8(4):624-9.
    View in: PubMed
    Score: 0.005
  31. Upregulation of prostaglandin E2 and interleukins in the central nervous system and peripheral tissue during and after surgery in humans. Anesthesiology. 2006 Mar; 104(3):403-10.
    View in: PubMed
    Score: 0.005
  32. Metal degradation products: a cause for concern in metal-metal bearings? Clin Orthop Relat Res. 2003 Dec; (417):139-47.
    View in: PubMed
    Score: 0.004
  33. The effect of spinal instrumentation particulate wear debris. an in vivo rabbit model and applied clinical study of retrieved instrumentation cases. Spine J. 2003 Jan-Feb; 3(1):19-32.
    View in: PubMed
    Score: 0.004
  34. The potential role of the osteoblast in the development of periprosthetic osteolysis: review of in vitro osteoblast responses to wear debris, corrosion products, and cytokines and growth factors. J Arthroplasty. 2001 Dec; 16(8 Suppl 1):95-100.
    View in: PubMed
    Score: 0.004
  35. Osteolysis: basic science. Clin Orthop Relat Res. 2001 Dec; (393):71-7.
    View in: PubMed
    Score: 0.004
  36. Metal release and excretion from cementless titanium alloy total knee replacements. Clin Orthop Relat Res. 1999 Jan; (358):173-80.
    View in: PubMed
    Score: 0.003
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.