Nadim  Hallab  to  Female
                            
                            
                                This is a "connection" page, showing publications  Nadim  Hallab  has written about  Female.
                            
                            
                            
                                
                                    
                                            
    
        
        
        
            Connection Strength
            
                
            
            0.673
         
        
        
     
 
    
        
        - 
            COVID-19 (SARS-CoV-2) lymphocyte responses are associated with inflammatory biomarkers in total joint replacement surgery candidates pre-operatively. J Orthop Surg Res. 2021 Jun 30; 16(1):415.
            
            
                Score: 0.057
             
- 
            Metal-induced delayed type hypersensitivity responses potentiate particle induced osteolysis in a sex and age dependent manner. PLoS One. 2021; 16(5):e0251885.
            
            
                Score: 0.056
             
- 
            Transition from metal-DTH resistance to susceptibility is facilitated by NLRP3 inflammasome signaling induced Th17 reactivity: Implications for orthopedic implants. PLoS One. 2019; 14(1):e0210336.
            
            
                Score: 0.048
             
- 
            Stainless steel wear debris of a scoliotic growth guidance system has little local and systemic effect in an animal model. J Orthop Res. 2018 07; 36(7):1980-1990.
            
            
                Score: 0.045
             
- 
            Females with Unexplained Joint Pain Following Total Joint Arthroplasty Exhibit a Higher Rate and Severity of Hypersensitivity to Implant Metals Compared with Males: Implications of Sex-Based Bioreactivity Differences. J Bone Joint Surg Am. 2017 Apr 19; 99(8):621-628.
            
            
                Score: 0.042
             
- 
            CORR Insights(?): do patients with a failed metal-on-metal hip implant with a pseudotumor present differences in their peripheral blood lymphocyte subpopulations? Clin Orthop Relat Res. 2015 Dec; 473(12):3915-7.
            
            
                Score: 0.039
             
- 
            Metal sensitivities among TJA patients with post-operative pain: indications for multi-metal LTT testing. J Long Term Eff Med Implants. 2014; 24(1):37-44.
            
            
                Score: 0.034
             
- 
            Implant debris particle size affects serum protein adsorption which may contribute to particle size-based bioreactivity differences. J Long Term Eff Med Implants. 2014; 24(1):77-88.
            
            
                Score: 0.034
             
- 
            Growth guidance system for early-onset scoliosis: comparison of experimental and retrieval wear. Spine (Phila Pa 1976). 2013 Aug 15; 38(18):1546-53.
            
            
                Score: 0.033
             
- 
            Asymptomatic prospective and retrospective cohorts with metal-on-metal hip arthroplasty indicate acquired lymphocyte reactivity varies with metal ion levels on a group basis. J Orthop Res. 2013 Feb; 31(2):173-82.
            
            
                Score: 0.031
             
- 
            In vivo response to cross-linked polyethylene and polycarbonate-urethane particles. J Biomed Mater Res A. 2010 Apr; 93(1):227-34.
            
            
                Score: 0.026
             
- 
            Cytokine assay of the epidural space lavage in patients with lumbar intervertebral disk herniation and radiculopathy. J Spinal Disord Tech. 2006 Jun; 19(4):266-9.
            
            
                Score: 0.020
             
- 
            Lymphocyte responses in patients with total hip arthroplasty. J Orthop Res. 2005 Mar; 23(2):384-91.
            
            
                Score: 0.018
             
- 
            Immune responses correlate with serum-metal in metal-on-metal hip arthroplasty. J Arthroplasty. 2004 Dec; 19(8 Suppl 3):88-93.
            
            
                Score: 0.018
             
- 
            Lymphocyte transformation testing for quantifying metal-implant-related hypersensitivity responses. Dermatitis. 2004 Jun; 15(2):82-90.
            
            
                Score: 0.017
             
- 
            Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements. J Orthop Res. 2004 Mar; 22(2):250-9.
            
            
                Score: 0.017
             
- 
            Differential lymphocyte reactivity to serum-derived metal-protein complexes produced from cobalt-based and titanium-based implant alloy degradation. J Biomed Mater Res. 2001 Sep 05; 56(3):427-36.
            
            
                Score: 0.014
             
- 
            Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal-protein complexes produced from cobalt-base and titanium-base implant alloy degradation. Mol Cell Biochem. 2001 Jun; 222(1-2):127-36.
            
            
                Score: 0.014
             
- 
            A triple assay technique for the evaluation of metal-induced, delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty. J Biomed Mater Res. 2000 Sep; 53(5):480-9.
            
            
                Score: 0.013
             
- 
            Systemic metal-protein binding associated with total joint replacement arthroplasty. J Biomed Mater Res. 2000 Mar 05; 49(3):353-61.
            
            
                Score: 0.013
             
- 
            Antioxidant impregnated ultra-high molecular weight polyethylene wear debris particles display increased bone remodeling and a superior osteogenic:osteolytic profile vs. conventional UHMWPE particles in a murine calvaria model. J Orthop Res. 2016 05; 34(5):845-51.
            
            
                Score: 0.010
             
- 
            Effect of a second joint arthroplasty on metal ion levels after primary total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2013 Oct; 42(10):E84-7.
            
            
                Score: 0.008
             
- 
            Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*. J Bone Joint Surg Am. 2013 Mar 20; 95(6):512-8.
            
            
                Score: 0.008
             
- 
            Micrometer-sized titanium particles can induce potent Th2-type responses through TLR4-independent pathways. J Immunol. 2011 Dec 15; 187(12):6491-8.
            
            
                Score: 0.007
             
- 
            Synovial fluid biomarkers for periprosthetic infection. Clin Orthop Relat Res. 2010 Aug; 468(8):2017-23.
            
            
                Score: 0.007
             
- 
            Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear. J Bone Joint Surg Br. 2010 Jan; 92(1):38-46.
            
            
                Score: 0.006
             
- 
            Multiple freeze-thaw cycled meniscal allograft tissue: A biomechanical, biochemical, and histologic analysis. J Orthop Res. 2008 Jan; 26(1):49-55.
            
            
                Score: 0.006
             
- 
            Explantation and analysis of the first retrieved human acetabular cup made of polycarbonate urethane: a case report. J Long Term Eff Med Implants. 2008; 18(1):75-83.
            
            
                Score: 0.006
             
- 
            The multi-suture technique for rotator cuff repair: a biomechanical evaluation. Orthopedics. 2007 11; 30(11):910-9.
            
            
                Score: 0.006
             
- 
            A critical evaluation of discography in patients with lumbar intervertebral disc disease. Spine J. 2008 Jul-Aug; 8(4):624-9.
            
            
                Score: 0.005
             
- 
            Wear particles. J Bone Joint Surg Am. 2006 Apr; 88 Suppl 2:99-102.
            
            
                Score: 0.005
             
- 
            The combination of pamidronate and calcitriol reverses particle- and TNF-alpha-induced altered functions of bone-marrow-derived stromal cells with osteoblastic phenotype. J Bone Joint Surg Br. 2004 Jul; 86(5):759-70.
            
            
                Score: 0.004
             
- 
            Metal release and excretion from cementless titanium alloy total knee replacements. Clin Orthop Relat Res. 1999 Jan; (358):173-80.
            
            
                Score: 0.003
             
- 
            Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am. 1998 Oct; 80(10):1447-58.
            
            
                Score: 0.003